POSEIDON 7 NEW-C3_en_Ver.1.0_33/12
Service / Repair
26
F
Pic. F4: Oil container
Identify the machine version at the
dataplate.
Find the techincal data for the machine
version in this manual chapter ”A”.
Pic. F1: Data Plate Pic. F2: Cabinet
Pic. F3: E– box
1
1
The lid for the electrical box is fitted with
2 x torx T20 screws.
Remove the screws and push the lid back-
wards to open the E-box.
The oil container is fitted to the pump by the 2x
Torx 20 screws.
The cabinet is demounted by turning the two
lock screws (1) on top of the cabinet.
Open the cabinet and pull forward.