F
C3 Pump
Water inlet filter is placed in the housing for
hose connector. Remove the circlip and filter
check for impurities.
Pic. F5: Water inlet filter
By-pass valve.
Pic. F6: Water outlet/ Injector
1. The injector nozzle is placed in the water
outlet and is dismounted with a 10mm
socket wrench.
2. Start/stop piston is placed behind the
out let coupling.
Pic. F7: By-pass system
1.
2.
All important wear parts in the by-pass system are available as spare