7
Model
SIM55
SIM75
Power supply(V/Ph/Hz)
208-230V~/60Hz
208-230V~/60Hz
Rated Ambient Temp Range (°F)
23~104
23~104
1
Heating Capacity (kBtu/h)
52.9
73.6
1
COP
6.0
5.9
2
Heating Capacity (kBtu/h)
33.78
46.54
2
COP
4.0
4.0
Maximum Water Outlet Temp. (°F)
104
104
Rated Water Flow (gpm)
23.8
31.5
Rated Water Pressure Drop (psi)
3.77
1.95
Maximum Input Power (kBtu/h)
14.0
17.4
Fan Motor Rating Load (FLA) (A)
0.4
1.1
Fan Motor Horsepower (Hp)
0.123
0.200
Compressor Rated Load RLA (A)
15.7
21.0
Compressor Lock Rotor Amperage (LRA) (A)
86
112
Minimum Circuit Ampacity (A)
18.5
11
Maximum Over-Current Protection (A)
35
27.8
Refrigerant Quantity (lbs)
R410A/3.417
R410A/4.409
Dry Weight (lbs)
134.5
171.9
Net Dimensions W×D×H (inches)
39.2×15.2×25.9
45.2×17.9×30.1
Water Pipe Connection
mm
48.3
48.3
Water Proof Class
IPX4
IPX4
Electricity Shock Proof Class
Refrigerant Side Pressure Limits (psi)
638/217
638/217
Water Side Pressure Limits (psi)
101.5
101.5
Ambient Temperature
(DB/WB) 80.6
°
F/71.2
°
F
Water Inlet/Outlet Temperature
80
°
F
Ambient Temperature
(DB/WB) 50
°
F/44.3
°
F
Water Inlet Temperature
80
°
F
The technical specifications of our heat pumps are provided for information purposes only. We
reserve the right to make changes without notice.
3. INSTALLATION

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Nirvana DISTINCTION SIM55 and is the answer not in the manual?

Nirvana DISTINCTION SIM55 Specifications

General IconGeneral
BrandNirvana
ModelDISTINCTION SIM55
CategoryHeat Pump
LanguageEnglish

Related product manuals