Operator’s Manual
Avant
®
9600
Digital Pulse Oximeter
01230123
English

Table of Contents

Questions and Answers

  • S
    Shirley WeaverAug 2, 2025
    What to do if an error code appears on Nonin Medical Equipment?
    • L
      Larry CarterAug 2, 2025
      To remove the error code on your Nonin Avant 9600 Medical Equipment, turn the unit off and then back on again. If the error persists, disconnect all power (AC and battery), and then reconnect the power and turn the unit back on. If the error still persists, note the error code and contact NONIN Customer Support.
  • C
    Christy DavisAug 6, 2025
    What to do if a dash appears in the %SpO display on Nonin Medical Equipment?
    • S
      Sandra McculloughAug 6, 2025
      If a dash (-) appears in the %SpO display on your Nonin Medical Equipment, it usually indicates a poor signal from the finger. Try repositioning the finger or inserting a different finger, and ensure the sensor remains motionless for at least 10 seconds. You can also try positioning the sensor at a different site. If the finger was removed, reinsert it and keep the sensor motionless. If the issue persists, turn the unit off, check all connections, and retry.
  • J
    Jimmy CarrAug 11, 2025
    Why I am unable to obtain a green pulse display on the bargraph on Nonin Avant 9600?
    • M
      mark07Aug 11, 2025
      If you are unable to obtain a green pulse display on the bargraph of your Nonin Medical Equipment, apply the sensor correctly and reduce or eliminate any interference. Make sure that the sensor is not placed on the same arm being used for other patient therapies or diagnostics (e.g., blood pressure cuff). Ensure that the sensor is securely attached to the Avant 9600. Shield the sensor from the light source and apply the sensor to a finger without artificial or polished nails. Reduce patient motion.
  • S
    Shawn HardinAug 16, 2025
    Why can't I hear audible alarms on my Nonin Avant 9600?
    • A
      Alexandra GrossAug 16, 2025
      If your Nonin Avant 9600 Medical Equipment is in Alarm mode but you can't hear any audible alarms, check if the 2-minute Alarm Silence button is activated. If it is, press the Alarm Silence button again to re-engage the alarm volume, or simply wait for two minutes for the alarm tones to automatically re-engage. Also, verify the position of option switch 1. If it's in the UP position and the unit’s volume is set to zero, adjust the alarm volume or return the switch to the DOWN position to enable audible alarms.
  • B
    Brian WeaverAug 22, 2025
    What to do if Nonin Medical Equipment will not operate on batteries?
    • C
      Carl NguyenAug 22, 2025
      If the Avant 9600 Medical Equipment will not operate on batteries, check the battery pack connection. If the connection is correct, plug in the Avant 9600 AC Adapter to charge the battery pack. If the problem persists, contact NONIN Customer Support for repair or replacement.
  • L
    Lauren McdonaldAug 27, 2025
    Why is my Nonin Avant 9600 Medical Equipment not recording data?
    • S
      Sandra MorrisAug 27, 2025
      If your Nonin Avant 9600 Medical Equipment is not recording data, the battery may be low. Recharge the battery. If the battery is missing, contact your distributor or NONIN Customer Support for repair or replacement.

Summary

Indications for Use

Warnings

Provides critical safety information and precautions for proper device operation and patient care.

Cautions

Outlines precautions to prevent device damage, inaccurate readings, or minor patient injury.

Displays, Indicators, and Controls

Front Panel Buttons and Controls

Details the functions of the ON/STANDBY, Time/Date, Volume, and Alarm Silence buttons.

Installing the Batteries

Operating the Avant 9600

Alarms and Limits

High Priority Alarms

Describes immediate attention alarms, their indicators, and default settings.

Memory and Data Output Features

Memory and Data Management

Covers device memory, nVISION software, and serial data output options.

Troubleshooting

Service, Support, and Warranty

Warranty Information

Details the warranty period and terms for the Avant 9600 and its components.