Operators Manual
Avant
®
9700
Digital Pulse Oximeter
English

Table of Contents

Questions and Answers

  • E
    Elizabeth CruzAug 18, 2025
    What to do if an error code appears on my Nonin Avant 9700 Medical Equipment?
    • R
      Rhonda RamosAug 19, 2025
      If an error code appears, the Avant 9700 has encountered an error. First, turn the unit off and then back on again to remove the error code. If the error persists, disconnect all power (AC and battery), and then reconnect the power and turn the unit back on. If the error still persists, note the error code and contact your distributor or NONIN Customer Support.
  • K
    Kendra AndrewsAug 23, 2025
    How to fix a Nonin Medical Equipment device that will not activate?
    • S
      Sarah GrantAug 23, 2025
      If your Nonin device isn't activating, it might be due to several reasons: the device may have no power, so plug in the AC power supply. Also, the battery pack might be connected incorrectly, so check the battery pack connector orientation. If the battery pack is not charged, plug in the device AC power supply to charge it. Note that new battery packs must complete one charge/discharge/recharge cycle before the Battery LED displays the actual capacity.
  • J
    Jason EdwardsAug 26, 2025
    What to do if a dash appears in the %SpO display on Nonin Avant 9700 Medical Equipment?
    • D
      Donna WhiteheadAug 26, 2025
      If a dash appears in the %SpO display, it indicates an inadequate signal from the finger. Try repositioning the sensor or applying it to a different finger, and keep the sensor motionless for at least 10 seconds. Warming the sensor application site may also help. The dash may also appear if the finger was removed from the sensor, so ensure proper placement.
  • M
    Mrs. Melinda PalmerAug 28, 2025
    Why can't I hear audible alarms when my Nonin Avant 9700 Medical Equipment unit is in Alarm mode?
    • R
      Regina BradyAug 28, 2025
      If you can't hear audible alarms while the unit is in Alarm mode, the 2-minute Alarm Silence button may be activated. Press the Alarm Silence button to activate the alarm volume, or wait for 2 minutes, after which the alarm tones will automatically activate. Alternatively, if option switch 1 is in the UP position, the unit’s volume may be set to zero. Adjust the alarm volume, or return option switch 1 to the DOWN position if audible alarms are required.
  • G
    Gregory GillAug 30, 2025
    What to do if a dash appears in the %SpO display on my Nonin Medical Equipment?
    • A
      Angela PhillipsAug 30, 2025
      If a dash appears in the %SpO display, it indicates a poor signal from the digit is being detected or the digit was removed from the sensor. Try repositioning the digit or inserting a different digit, ensuring the sensor remains motionless for at least 10 seconds. If the digit was removed, reinsert it and keep the sensor motionless. If the issue persists, turn the unit off, check all connections, and retry.
  • M
    Melissa RobertsonSep 1, 2025
    Why does my Nonin Avant 9700 Medical Equipment show frequent pulse quality indications?
    • K
      khaneySep 1, 2025
      Frequent or steady pulse quality indications can occur due to excessive ambient light, application of the Avant 9700 to a polished or artificial fingernail, or excessive patient motion. Shield the sensor from the light source, apply the sensor to a finger without artificial or polished nails, and reduce patient motion.
  • F
    fosterdanielSep 4, 2025
    How to fix no green pulse display on the bargraph of Nonin Avant 9700?
    • G
      Gabrielle GreenSep 4, 2025
      If you're unable to obtain a green pulse display on the bargraph, the patient's pulse strength might be low, or circulation is reduced because of excess pressure on the sensor, or the digit is cold. Try repositioning the digit or inserting a different digit, and keep the sensor motionless for at least 10 seconds. Allow the digit to rest comfortably without squeezing or pressing the sensor on a hard surface. Warm the digit by rubbing or covering with a blanket.
  • H
    Holly PhamSep 6, 2025
    What to do if I still can't get a green pulse display on my Nonin Avant 9700 Medical Equipment?
    • Y
      youngcalebSep 6, 2025
      If you are still unable to obtain a green pulse display, ensure the sensor is applied correctly. Possible interference from sources like arterial catheters, blood pressure cuffs, electrosurgical procedures, or infusion lines might be the cause. Reduce or eliminate any interference and ensure the sensor is not placed on the same arm being used for other patient therapies or diagnostics, such as a blood pressure cuff. Also, check that the red LED is illuminated in the digit insertion area and that the sensor is securely attached to the device.
  • R
    rherreraSep 8, 2025
    Why won't my Nonin Medical Equipment Avant 9700 operate on batteries?
    • T
      Tiffany Williams MDSep 8, 2025
      If the Avant 9700 will not operate on batteries, it could be due to several reasons: * The battery pack is inserted incorrectly. Check the battery pack connection. * The battery pack is not charged. Plug in the Avant 9700 AC Adapter to charge the battery pack. * The battery pack is inoperable. Contact your distributor or NONIN Customer Support for repair or replacement.
  • K
    Kevin GordonSep 12, 2025
    Why are there no audible alarms on my Nonin Avant 9700 Medical Equipment?
    • L
      Lawrence HawkinsSep 12, 2025
      If the unit is in Alarm mode but no audible alarms can be heard, the 2-minute Alarm Silence button may be activated. Press the Alarm Silence button to re-engage alarm volume, or wait for two minutes—and alarm tones will automatically re-engage. Alternatively, DIP switch 1 might be in the UP position, and the unit’s volume is set to zero. Adjust the alarm volume, or return DIP switch 1 to the DOWN position if you desire audible alarms.

Summary

Indications for Use and Safety

Warnings

Critical safety precautions and contraindications for using the device.

Cautions

Important considerations and potential risks associated with device operation.

Guide to Symbols and Device Interface

Symbol Definitions

Explanation of symbols used on the device and in the manual.

Displays, Indicators, and Controls Overview

Overview of front panel layout, buttons, displays, and indicators.

Display Elements and Indicator LEDs

Details on %SpO2, Pulse Rate displays, LEDs, and indicator descriptions.

Device Operation and Navigation Buttons

Functionality of front panel buttons for operation and navigation.

Device Setup and Operation

Installing the Batteries and Serial Port Cover

Instructions for installing batteries and the serial port cover.

Operating the Avant 9700

Steps for startup, sensor verification, and setting default parameters.

Operator Functions

Core device operations like power, battery, display, and print-on-demand.

Advanced Operator Functions

Managing custom settings, recalling previous configurations, and patient security mode.

Option Switches Configuration

Details on configuring the eight option switches for device behavior.

Data Views and Alerts

LCD Display Views

Description of the primary waveform display showing SpO2 and pulse rate.

Trend Data Views

How to view historical SpO2 and pulse rate data over 24 hours.

Data Analysis and Alerts

Analysis of stored data using histogram format and nurse call functionality.

Alarms, Security, and Error Handling

Alarms and Limits Management

Details on high priority alarms, their indicators, and default settings.

Alarm Conditions and Settings

Information on medium priority, watchdog alarms, and alarm limit adjustments.

Alarm Handling and Settings

How to silence, recall, and manage alarm lock states.

Patient Security and Error Codes

Managing patient security mode and understanding error code descriptions.

Error Code Resolution

Procedure for clearing specific error codes (06, 08, 10).

Memory, Data Output, and System Integration

Memory and Data Management

Details on data storage, management, and using nVISION software.

Data Output Options

Options for real-time and print-on-demand data output.

Medical System Integration

Considerations for integrating the device with other medical systems.

Maintenance and Troubleshooting

Care and Maintenance

Instructions for cleaning the device safely and effectively.

Parts and Accessories

Information on obtaining replacement parts and accessories.

Troubleshooting

Solutions for device activation, pulse display, and signal issues.

Troubleshooting Common Issues

Resolving SpO2 display problems and alarm/recording failures.

Service, Warranty, and Technical Information

Service, Support, and Warranty

Procedures for returns and warranty details for the device.

Warranty Disclaimer

Exclusionary statement regarding express and implied warranties.

Technical Information

Manufacturer's declarations, emissions, and immunity data.

Electromagnetic Compatibility

Immunity test levels for ESD and transients.

RF Interference Guidance

Recommendations for separation distances from RF transmitters.

Equipment Response Time

Information on signal loss handling and response times for SpO2 and pulse rate.

Testing Summary and Principles

Summary of accuracy testing and principles of pulse oximetry operation.

Specifications

Technical details for the oximeter, system, environment, and power.

Technical Classifications and Outputs

Device classifications and electrical specs for nurse call output.

Nonin Avant 9700 Specifications

General IconGeneral
TypePulse Oximeter
Measurement ParametersSpO2, Pulse Rate
DisplayLED
ConnectivityUSB
SpO2 Range0 to 100%
Battery TypeAA Alkaline
Data Storage72 hours of memory
Perfusion Index Range0.2 to 20%
Accuracy±2% SpO2
Operating Temperature0°C to 50°C
Storage Temperature-20 to 60 °C
Humidity10% to 95% non-condensing

Related product manuals