46
Theboomsoperatebackwards
1. Ensurethe raiselines are connected to the “B” ports and the lower lines are connected to the “A”
ports.
2. Ensuretheelectricalconnectionsarecorrect.
3. Ensurethevalvesareconfigured(mapped)correctly.
Theboomsmovetoofastortooslow
1. Ensuretheorificesareinstalledcorrectly.Ifthe“B”portisbackwards,theboomwillmoveupslowly
anddownfast.Ifthe“A”portisbackwards,itwillraiseslowlyandmaychatterwhengoingdown.
2. Ensuretheorifices
arenotjammedintheport.Tryremovingandreinstallingtheorifices.
3. Checktoseeifthefilterisplugged.Thefiltercanberemovedtotest,butitmustbereinstalled.
4. Ensure the correct “A” and “B” port NORAC fittings are used.If the wrong fittings are used,
the