Installation Manual 21
- If a less efcient energy source is not available:
- An audible alarm starts.
- A fault code shows in the center display.
- Refer to the “Fault Codes” section of this manual.
Set the controls to manual mode operation:
- Push the ON / OFF button to turn the refrigerator on.
- Push and hold the MODE button until the letters “ AC” show in the center display and then release.
- After ten seconds, the “AC” goes off and only a green power ON light remains.
- Push and hold the MODE button until the letters “LP” show in the center display and then release.
- After ten seconds, the “LP” goes off and only a green power ON light remain
Do a test of the gas safety valve:
1. Start up the refrigerator in the manual mode operation.
2. Open the lower intake vent.
3. Remove one wire from the solenoid of the gas safety valve at the rear of the refrigerator.
4. Within 30 seconds, the ame should extinguish. This means that the gas safety valve is operating correctly.
5. Put the wire back on the solenoid of the gas safety valve.
6. Close the lower intake vent.
Shut down - all models:
To shut down the refrigerator, push and hold the ON/OFF button for one second.

Table of Contents

Other manuals for Norcold 1210

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Norcold 1210 and is the answer not in the manual?

Norcold 1210 Specifications

General IconGeneral
TypeAbsorption Refrigerator
AC Voltage120 V
DC Voltage12 V
Power SourceAC/DC
RefrigerantR-134a

Related product manuals