Abnormal Condition
Mode Selector set to off, CHECK
light illuminated.
Probable Cause:
A. Defective fluorescent light
(see probable cause on
page 5-31)
B. Defective Power Supply
C. Corrosion in cable connec-
tors
D. Defective cable
Abnormal Condition
Mode Selector set to GAS, LP
light is not illuminated, refrigerator
working on gas
Cause: Defective Eyebrow board
Abnormal Condition
Mode Selector set to GAS, LP
light is illuminated, the flame did
not light, and the CHECK light is
not illuminated
Probable Cause:
A. Defective Eyebrow board
B. Defective Ignition Module
C. Defective cable
Figure 5.68
Figure 5.69
Figure 5.70