NORDAC FLEX (SK 200E ... SK 235E)Users Manual for Frequency Inverters
236 BU 0200 en-3118
Pos: 69 1 /Anlei tung en/El ektr onik/FU und Star ter/6 . Meld ungen zum Betr iebsz usta nd/FA Q Betri ebsst örung en @ 9\mod_1448963314277_388.docx @ 268440 @ 2 @ 1
6.4 FAQ operational problems
Fault Possible cause Remedy
Pos: 692 /A nleit ung en/El e ktr onik /FU und Star ter /6. M eldung en zu m B etrie bsz ust and /Betr ie bss tör ung en (A ufli st ung) /FA Q B etri ebss tör ungen _01 [S K 1x5E, SK 2 xxE] @ 9\mod_1448963514987_388.docx @ 268902 @ @ 1
Device will not start (all LEDs
off)
No mains voltage or wrong mains
voltage
SK 2x5E: No 24 V DC control voltage
Check connections and supply
cables
Check switches / fuses
Pos: 69 3 /Anlei tu nge n/El ektr oni k/FU un d St art er/6 . M eld ung en z um B etr iebs zus ta nd/B etri ebss tör ung en (A uflis tung )/F AQ Betr ie bsst örung en _02 [S K 1x0E, SK 2xxE, SK 2xx E-FDS] @ 9\ mod_1448963508461_388.docx @ 268836 @ @ 1
Device does not react to
enabling
Control elements not connected
Incorrect control word source setting
Right and left enable signals present
simultaneously
Enable signal present before device
ready for operation (device expecting a
0 1 edge)
Reset enable
Change over P428 if
necessary: "0" = device
expecting a 01 edge for
enable / "1" = device reacts to
"Level"
Danger: Drive can start up
independently!
Check control connections
Check P509
Pos: 69 4 /Anlei tung en/El ektr onik/FU und Star ter/6 . Meld ungen zum Betr iebs zus ta nd/B etri ebss tör ung en (A uflis tung )/F AQ Betr ie bsst örung en _03 [S K 1 x0E, SK 2xx E, S K 2x xE-FD S] @ 9\mod_1448963505438_388.docx @ 268803 @ @ 1
Motor will not start in spite of
enable being present
Motor cables not connected
Brake not ventilating
No setpoint specified
Incorrect setpoint source setting
Check connections and supply
cables
Check control elements
Check P510
Pos: 69 5 /Anlei tung en/El ektr onik/FU und Star ter/6 . Meld ungen zum Betr iebsz usta nd/Betr iebss tör ungen (Auflis tung) /FAQ Betrie bsstör ungen _04 [S K 1xxE, SK 2xxE, SK xxxE-FD S] @ 9\mod_1448963501354_388.docx @ 268770 @ @ 1
Device switches off without
error message when load
increases (increased
mechanical load / speed)
Mains phase missing
Check connections and supply
cables
Check switches / fuses
Pos: 696 /A nleit ung en/El e ktr onik /FU und Star ter /6. M eldung en zu m B etrie bsz ust and /Betr ie bss tör ung en (A ufli st ung) /FA Q B etri ebss tör ungen _05 [S K 1x0E, SK 2xxE, S K 2xxE-FD S] @ 9\mod_1448963497620_388.docx @ 268737 @ @ 1
Motor rotating in wrong
direction
Motor cable U-V-W interchanged
Motor cable Switch 2 phases
Alternatively:
Switch parameter P420
right / left enable functions
Switch control word bits
11/12 (with bus actuation)
Pos: 69 7 /Anlei tu nge n/El ektr oni k/FU un d St art er/6 . M eld ung en z um B etr iebs zus ta nd/B etri ebss tör ung en (A uflis tung )/F AQ Betr ie bsst örung en _06 [SK 1x0, SK 2xxE, SK 2xxE-FDS ] @ 9 \mod_1448963480910_388.docx @ 268704 @ @ 1
Motor not reaching required
speed
Maximum frequency parameter setting
too low
Check P105
Pos: 69 8 /Allg emein/ Allg emeing ültig e Mod ule/---------Sei tenumbr uch ko mpakt --------- @ 13\mod_1476369695906_0.docx @ 2265495 @ @ 1