SK 500E – Brief instructions for frequency inverters
40 BU 0540 EN-1516
Parameter
No. [Array]
Designation
Factory
setting
Supervisor
Setting after commissioning
P 1
P 2
P 3
P 4
P244 (P)
Peak current [A]
5
S
P245 (P)
Oscillation damping PMSM VFC
[%]
25 S
P246 (P)
Mass Inertia PMSM [kg*cm²]
5
S
P247 (P)
Switch-over freq. VFC PMSM
[%]
25 S
*) dependent on FI power or P200/P220
CONTROL PARAMETERS, encoder input, only SK 520E/53xE
P300 (P)
Servo Mode [On / Off]
0
P301
Rotary encoder resolution
6
P310 (P)
Speed controller P [%]
100
P311 (P)
Speed controller I [%/ms]
20
P312 (P)
Torque current controller P [%]
400
S
P313 (P)
Torque current controller I [%/ms]
50
S
P314 (P)
Torq. curr. ctrl. limit [V]
400
S
P315 (P)
Field current controller P [%]
400
S
P316 (P)
Field current controller I [%/ms]
50
S
P317 (P)
Limit, field current controller [V]
400
S
P318 (P)
Weak field controller P [%]
150
S
P319 (P)
Weak field controller I [%/ms]
20
S
P320 (P)
Weak field limit [%]
100
S
P321 (P)
Speed control I release time
0
S
P325
Function encoder
0
P326
Encoder conversion
01:00
P327
Speed slip error [rpm]
0 (off)
P328
Speed slip delay [rpm]
0 (off)
P330
Regulation PMSM
0
S
P331
Switchover freq. PMSM [%]
15
S
P332
Hyst. Switchover PMSM [%]
5
S
P333
Flux feedback factor PMSM [%]
25
S
P334
Encoder offset PMSM [rev]
0
S
P350
PLC functionality
0 (off)
P351
PLC setpoint selection
0
P353
Bus status via PLC
0
P355 [-01]
PLC integer setpoint
0
P355 [-02]
PLC integer setpoint
0
P355 [-03]
PLC integer setpoint
0
P355 [-04]
PLC integer setpoint
0
P355 [-05]
PLC integer setpoint
0
P355 [-06]
PLC integer setpoint
0
P355 [-07]
PLC integer setpoint
0
P355 [-08]
PLC integer setpoint
0
P355 [-09]
PLC integer setpoint
0
P355 [-10]
PLC integer setpoint
0
P356 [-01]
PLC long setpoint
0
P356 [-02]
PLC long setpoint
0
P356 [-03]
PLC long setpoint
0
P356 [-04]
PLC long setpoint
0
P356 [-05]
PLC long setpoint
0
P360 [-01]
PLC display value
0
P360 [-02]
PLC display value
0
P360 [-03]
PLC display value
0
P360 [-04]
PLC display value
0
P360 [-05]
PLC display value
0
P370
PLC status
CONTROL TERMINALS
P400 (P)
Function Analogue input 1
1
P401
Analog input mode 1
0
S
P402
Adjustment 1: 0% [V]
0.0
S
P403
Adjustment 1: 100% [V]
10.0
S
P404
Filter On input 1 [ms]
100
S

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Nord Drivesystems SK 515E Series and is the answer not in the manual?

Nord Drivesystems SK 515E Series Specifications

General IconGeneral
BrandNord Drivesystems
ModelSK 515E Series
CategoryDC Drives
LanguageEnglish

Related product manuals