NORDAC SK 700E Operating Manual
12 Subject to technical alterations BU 0700 EN
2.5 Line choke (accessories)
To reduce input side current harmonics, additional inductivity
can be installed into the line supply to the inverter.
These chokes are specified for a maximum supply voltage of
480V at 50/60 Hz.
The protection class of the chokes is IP00 and they must
therefore be installed in a control cabinet.
For frequency inverters with an output of 45 kW or more, a
line choke is recommended where several devices are being
used, in order to avoid possible adverse effects of one device
on another. In addition, the charging currents (mains voltage
fluctuations) are significantly reduced.
Inverter type
NORDAC
SK 700E
Input choke 3 x 380 - 480 V
Length
L1
Width
B1
Depth
T
Detail: mounting
Connection
Type
Permanent
current
Inductance
Length
L2
Width
B2
Mounting
1.5 ... 2.2 kW SK CI1-460/6-C 6 A 3 x 4.88 mH 71 125 140 55 100 M4 4
3.0 ... 4.0 kW SK CI1-460/11-C 11 A 3 x 2.93 mH 84 155 160 56.5 130 M6 4
5.5 ... 7.5 kW SK CI1-460/20-C 20 A 3 x 1.47 mH 98 190 191 57.5 170 M6 10
11 ... 18.5 kW SK CI1-460/40-C 40 A 3 x 0.73 mH 118 190 191 77.5 170 M6 10
22 ... 30 kW SK CI1-460/70-C 70 A 3 x 0.47 mH 124 230 290 98 180 M6 35
37 ... 45 kW SK CI1-460/100-C 100 A 3 x 0.29 mH 148 230 290 122 180 M6 50
55 ... 75 kW SK CI1-460/160-C 160 A 3 x 0.18 mH 170 299 360 105 237 M8 95
90 ... 132 kW SK CI1-460/280-C 280 A 3 x 0.10 mH 190 290 270 133 240 M10 150
160 kW SK CI1-460/350-C 350 A 3 x 0.084 mH 190 300 270 107 224 M8 CU Bar
All dimensions in [mm]