EasyManua.ls Logo

nord NORDAC SK 700E - Basic I;O

nord NORDAC SK 700E
128 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
3.2 Customer unit
BU 0700 EN Subject to technical alterations 45
3.2.1 Basic I/O
(SK CU1-BSC, Option)
The Customer Unit Basic I/O provides sufficient control terminals for simple control
tasks and is therefore an economic solution for many applications.
1 analog input and 3 digital outputs are available to control the frequency inverter.
The analog differential input can process positive signals of 0...10V.
By means of a relay contact, brake control and even warnings to another system
can be initiated. There are a total of 13 different relay functions available.
The digital inputs of the Basic I/O can also be assigned analog functions (see
process controller, Chapter 8.2). Here, input voltages 10V are processed as 10V
signals and correspond to 100%.
(9V = 90%, ... , 0V=0%)
Connector Functions Maximum cross-section Parameter
X3.1 Output relay 1.5 mm
2
P434 ... P436
X3.2 Analog input 1.5 mm
2
P400 ... P408
X3.3 Digital inputs 1.5 mm
2
P420 ... P422
NOTE: All control voltages are based on a common reference potential!
Potentials AGND /0V und GND /0V are internally linked in the device.
The maximum total current 5/15V is 300mA
!
Floating contacts or
output of a PLC: 7,5...33V
(low = 0...3,5Volt)
Differential input 0...10 V
X3.1
X3.2
X3.3
01 REL1.1
02 REL1.2
11 VREF 10V
12 AGND /0V
13 AIN1 -
14 AIN1 +
21 DIG IN 1
22 DIG IN 2
23 DIG IN 3
42 VO +15V
Digital inputs:
DIG IN 1 = On right
DIG IN 2 = On left
DIG IN 3 = Parameter set bit 0
Output relay:
max. 2,0A
28V DC /230 V AC
U
REF
= 10 V / I
ma x
= 10 mA
0V, gnd
Power supply: 15V
PLC analog output: 0...10V
or potentiometer: 2...10kΩ

Table of Contents

Related product manuals