Nordson Sure Coat - Accessing and Changing Controller Settings; Configuring the Triggering Controller

Nordson Sure Coat
8 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
2
Accessing and Changing Controller Settings
Accessing Configuration and Setpoint
Menus
1. Press the MODE key until the desired mode
appears.
2. Press the OK key to enter the mode.
3. Press the SELECT+ or SELECT- keys to toggle
through the mode menus.
Changing Menu Settings
1. Press the OK key to enter edit mode. EDIT
appears next to the menu label. The value you
are editing will flash while you are in the edit
mode.
2. Press the SELECT+ or SELECT- keys to change
the value displayed below the menu label.
3. If you change a value but then decide to revert to
the old value, press the UNDO key. This key only
works while you are in edit mode.
4. Press the OK key to accept the value and exit
edit mode.
Changing Interface Language
NOTE: The default interface language is English.
1. Press the MODE key until SELECT LANGUAGE
appears.
2. Press the OK key to enter edit mode. The
currently selected language appears.
3. Press the SELECT+ or SELECT-keys until the
desired language appears.
4. Press the OK key to set the change and exit the
edit mode.
Configuring the Triggering Controller
The triggering controller must be configured and calibrated before trigger setup.
Configuration Steps
Menu Item Default Parameters and Functions
English/Metric English Choose English or Metric units.
Encoder Scale 1:1 Choose 1:1 or 1:2 encoder scale. Determines unit of movement per encoder
pulse. If set to 1:2, encoder signal is split so that one unit of movement is
equal to two encoder pulses, allowing finer resolution and more precise
triggering.
Clocking
Method
Encoder Choose Encoder or Timer. Timer is an internal clock. If you choose Timer,
the conveyor interlock is automatically enabled and cannot be disabled. The
conveyor interlock circuit must be connected when the timer is used.
User Conveyor
Speed
0.0 ft/min
or m/min
Enter speed of conveyor, in feet or meters per minute. Used for Timer
operation only, do not set if encoder is used.
Encoder Alarm Time 5.0 The Encoder Alarm can function in either of two ways, depending on how the
External Interlock menu item is set:
External Interlock Enabled: The encoder alarm is a delay (in seconds)
between the time the encoder stops pulsing and when an alarm message
appears on the display. Do not set this value to zero; doing so will cause the
trigger controller to malfunction. To disable the alarm set this value to a large
number.
External Interlock Disabled: The encoder alarm function is an encoder
pulsing stopped monitor. Refer to Encoder Pulsing Stopped Monitor for
setup instructions.
Sensor Alarm Time 90.0 Enter number of seconds after last sensor signal is received before alarm
message appears. Indicates sensor fault or photoeye-to-reflector
misalignment.
Continued...