EasyManuals Logo

Nordyne Q5RD Series User Manual

Nordyne Q5RD Series
24 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #18 background imageLoading...
Page #18 background image
18
Table 14. Charging Table for Q5RD-042K Series (3.5 Ton Units)
OUTDOOR TEMPERATURE (°. F)
0 102030405060
Suc.
Press
Liq.
Press.
Dis.
Temp.
Suc.
Press.
Liq.
Press.
Dis.
Temp.
Suc.
Press.
Liq.
Press.
Dis.
Temp.
Suc.
Press.
Liq.
Press.
Dis.
Temp.
Suc.
Press.
Liq.
Press.
Dis.
Temp.
Suc.
Press.
Liq.
Press.
Dis.
Temp.
Suc.
Press.
Liq.
Press.
Dis.
Temp.
33 217 136 48 239 137 63 261 138 78 283 139 92 295 144 107 319 154 121 343 163
34 224 134 49 245 135 64 266 136 79 287 137 93 302 141 108 326 149 122 350 157
35
231 132
50
251 133
65
271 134
80
290 135
94
309 139
109
333 145
123
357 151
36 238 130 51 257 131 66 275 132 81 294 133 95 316 136 110 340 140 124 364 145
37
245 128
52
262 129
67
280 130
82
298 131
96
323 133
111
347 136
125
371 139
38 252 126 53 268 127 68 285 128 83 301 129 97 330 130 112 354 131 126 378 133
39 259 124 54 274 125 69 290 126 84 305 127 98 337 127 113 361 127 127 385 126
REFRIGERANT CHARGING TABLES - HEATING MODE:
Shaded boxes indicate fl ooded conditions.
Rated design values. The suction pressure will vary from design value if outdoor air fl ow, entering dry bulb, or entering wet bulb temperatures vary.
1. All pressures are listed psig and all temperatures in °F
2. Discharge temperatures greater than charted values indicate an undercharged system.
OUTDOOR TEMPERATURE (° F)
0 102030405060
Suc.
Press
Liq.
Press.
Dis.
Temp.
Suc.
Press.
Liq.
Press.
Dis.
Temp.
Suc.
Press.
Liq.
Press.
Dis.
Temp.
Suc.
Press.
Liq.
Press.
Dis.
Temp.
Suc.
Press.
Liq.
Press.
Dis.
Temp.
Suc.
Press.
Liq.
Press.
Dis.
Temp.
Suc.
Press.
Liq.
Press.
Dis.
Temp.
34 216 127 49 234 128 63 251 129 78 269 130 93 275 135 109 294 145 124 313 154
35 223 125 50 240 126 64 256 127 79 272 128 94 282 133 110 301 140 125 320 148
36
230 123
51
246 124
65
261 125
80
276 126
95
289 130
111
308 136
126
327 142
37 237 121 52 251 122 66 266 123 81 280 124 96 296 127 112 315 131 127 334 136
38
244 119
53
257 120
67
270 121
82
283 122
97
303 124
113
322 127
128
341 129
39 251 117 54 263 118 68 275 119 83 287 120 98 310 121 114 329 122 129 348 123
40 258 115 55 269 116 69 280 117 84 291 118 99 317 118 115 336 118 130 355 117
Table 13. Charging Table for Q5RD-036K Series (3 Ton Units)

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Nordyne Q5RD Series and is the answer not in the manual?

Nordyne Q5RD Series Specifications

General IconGeneral
BrandNordyne
ModelQ5RD Series
CategoryHeat Pump
LanguageEnglish

Related product manuals