Secure the materials stop on the table.
Insert the guide-a-cut in the materials
stop on the table
Set the guide in the desired position
before tightening the screws
3.5 Electrical connections
Check that,
the voltage/phase supply corresponds to the information indicated on the motor plate.
Available power supply must have ground connection in conformity with safety regulations.
The connecting cables should have at least a 2.5mm
2
-section per phase.
3.6 Starting the machine
Connect the machine to the electrical supply. You can start it pressing the green button on the
switch. To stop the machine, press the red button. The red button is also the emergency switch.
3.7 Water cooling system
Fill the water pan with clean water to 1cm of the edge of the water tray.
Ensure that water is delivered adequately to both sides of the blade, as insufficient water supply
may result in premature failure of the diamond blade.
The water pump must never run without water. Always make sure that there is enough water in
the pan and refill if necessary.
In case of frost, empty the water cooling system from its water.