Installer's duties and responsibilities for system installation and compliance.
Describes the system using independent ductwork for supply and exhaust air.
Uses HRV with a forced air furnace distribution system for supply and exhaust.
Utilizes the furnace return duct for both supply air distribution and exhaust air collection.
Details available digital and mechanical control options for the ES Series.
Guidelines for connecting exterior ductwork, including insulation and vapour barriers.
Recommendations for mounting the HRV unit to minimize noise and maximize efficiency.
Best practices for duct installation, including bends, joints, and material selection.
Instructions for properly connecting the HRV condensate drain system.
Procedure for adjusting motor speeds to balance airflow between supply and exhaust.
Overview of the main circuit board's capabilities and connectivity options.
Describes the ES-T1 timer for timed high-speed ventilation in specific areas.
Explains the ES-M1 control for selecting standby, low speed, or high speed operation.
Details the ES-M2 control for timed low speed ventilation and standby cycles.
Introduces the ES-M3 control for recirculation, suitable for homes with secondary heating.
Basic control for continuous low speed and intermittent high speed based on humidity.
Humidity control with a 3-position switch for OFF, STANDBY, or CONTINUOUS modes.
Timer for timed high-speed ventilation, installable in kitchens, bathrooms, etc.
Information on using spring wound timers for continuous low speed or timed operation.
How to use a basic light switch for remote on/off functionality.
Recommends interlocking the HRV with the furnace blower for simplified duct systems.
Instructions for cleaning and replacing filters to maintain performance.
Guidance on cleaning fan blades and interior surfaces.
Procedures for cleaning the condensate drain pan and tubing.
How to remove and clean the HRV heat exchange core.
Checking and cleaning exterior vents to prevent obstructions.
Cleaning grills and inspecting/repairing ductwork insulation.
Diagram of the main control circuit board for the ES Series.
Explains jumper settings for defrost, recirculation, and furnace interlock configurations.
Wiring diagrams for ES170 and ES100 models.
Wiring details for connecting ES Series digital controls to the main board.
Wiring instructions for the DSTAT-1 dehumidistat control.
Wiring instructions for the WIN-1 Windsor mechanical control.
Wiring instructions for the WIN-20 Windsor timer control.
Wiring information for connecting low voltage switches to the unit.