OM0135
1
Air-Jacketed Automatic CO
2
Incubator
Models
NU-5510
NU-5510E
Operation and Maintenance Manual
October, 2010
Revision 12
(Series 6 & Higher)
Manufactured By:
NuAire, Inc.
2100 Fernbrook Lane
Plymouth, MN 55447
Toll-Free: 1-800-328-3352
In Minnesota: (763)-553-1270
Fax: (763)-553-0459

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the NuAire NU-5510E and is the answer not in the manual?

NuAire NU-5510E Specifications

General IconGeneral
ClassClass II, Type A2
TypeBiological Safety Cabinet
FiltrationHEPA filters
Power115V/60Hz
DescriptionThe NU-5510E is a Class II, Type A2 biosafety cabinet designed for personnel, product, and environmental protection.

Summary

Performance Parameters and Features

2.2 Key Control and Safety Features

Details dual sensors, control algorithm, CO2 recovery, door heating, and safety features.

Test Performance & Procedures

4.2 Electrical Tests

Details electrical safety tests like leakage, dielectric voltage, and grounding continuity.

4.3 Functional Tests

Describes tests for control systems, CO2, temperature, and humidity performance.

Warranty

Installation

Electrical Connection Requirements

CO2 Regulators

Correct Installation

DHD Autoflow Operation

Control System Overview

Simplified Operator Controls

Alarm and Error Notification

Diagnostic and Calibration Assists

Front Control Panel Descriptions

Rear Panel Detail

Run Mode Operator Interactions

Setup Mode Operator Interactions

Diagnostic and Checkout Procedures

8.8.1 Diagnostic Mode

How to access and use diagnostic modes for input/output testing.

Calibration

9.1 Chamber Temperature Calibration

Step-by-step guide to calibrate the chamber temperature within 1°C of operating temp.

Door and Perimeter Temperature Calibration

CO2 Calibration

9.4.1 CO2 Control Calibration

Calibrating the CO2 control system when measurements don't correlate to the display.

9.4.2 CO2 Sensor Calibration Routines

Detailed zero/span and injection calibration routines for the CO2 sensor.

CO2 Injection Calibration

CO2 System Auto Zero Calibration

Maintaining Your DHD Autoflow

Heated Decon Cycles

Chemical Decontamination of the Incubator Chamber

Error Indicators & Troubleshooting

Error Indicator Troubleshooting Guide

A table listing error codes, descriptions, and recommended checks/corrections.

Electrical/Environmental Requirements

Related product manuals