Temporary or permanent temperature bypass
This operation allows you to temporarily modify the floor temperature while you
are in the Automatic mode. Simply press on or buttons to select the desired
temperature, or the or button to select the Comfort or Econo settings you
have programmed. This temperature will be maintained until the beginning of the
next programmed schedule.
You can also switch to the Vacation setting for a prolonged absence by pressing
on and at the same time. The display will show icon. In that case,
the temperature bypass is permanent. To return to the normal operating mode,
press on Mode button.
If you wish to immediately return to the programmed settings, press on Mode
button twice.
1- Press on PGM button to access the programming mode.
2- Press on Day button 3 seconds to select every day of the week.
3- Press on Hour and Min buttons to enter 6:15 AM Prog. 1, ( ).
4- Press on PGM button to select Prog. 2 ( ) and Hour and Min buttons to
enter 8:15 AM.
5- Repeat step 4 to enter Prog. 3 (5:00 PM) and Prog. 4 (10:00 PM).
NOTE : When making modifications, make sure you are in the right
program.
To modify the Saturday and Sunday schedules:
6- Press on Day button until SA or SU is displayed.
7- Press on PGM button to select Prog. 1 ( ) and Hour and Min
buttons to enter 7:30 AM.
8- Press on PGM button to select Prog. 2 ( ) and then Clear button to
erase it.
9- Press on PGM button to select Prog. 3 ( ) and then Clear button to
erase it.
10- Press on PGM button to select Prog. 4 ( ) and then Hour and Min
buttons to enter 11:00 PM.
11- Press on Mode button to exit this function.
CHARACTERISTICS
Model: FTGF1P (120 VAC)
Supply: 120 VAC, 50/60 Hz
Load: 16.7 A maximum (Resistive only)
Power: 2000 watts (NI) @ 120 VAC
Ground fault circuit interrupter (GFCI): Class A (5 mA TRIP LEVEL)
Approvals: CSA / C, US
Display range: 0 to 60 °C (32 to 140 °F)
Setting range: 5 to 40 °C (40 to 104 °F)
Comfort default setting: 28 °C (82 °F)
Econo default setting: 18 °C (64 °F)
Storage: -20 to 50 °C (-4 to 120 °F)