LPN80
n
Installation Guide
Page 7
Operation
To Operate Fan
Use an ON/OFF switch or speed control to operate this
ventilator.
WARNING Before servicing or cleaning unit,
switch power off at service panel and lock the service
disconnecting means to prevent power from being
switched on accidentally. When the service disconnecting
means cannot be locked, securely fasten a prominent
warning device, such as a tag, to the service panel.
Cleaning and Maintenance
To Clean
For quiet and efficient operation, long life and attractive
appearance, remove Grille and vacuum interior of unit with
a dusting brush attachment.
The Motor is permanently lubricated and never needs
oiling. If the motor bearings are making excessive or
unusual noises, replace the Motor.
Troubleshooting
Symptom: The fan does not run.
• Checkforanopenfuseorcircuitbreakerinthebuilding’s
service panel.
• Checkthattheplug-inconnectionfortheMotorisseated
firmly in place.
• CheckthattheBlowerWheelspinsfreely
Symptom: The fan runs erratically.
• CheckthattheBlowerWheelisfirmlyattachedtothe
Motor shaft and both spin freely.
Symptom: The fan seems noisy.
• Checkthatthebackdraftdamperinthefan’sDuct
Connector pivots freely. Screws used to attach the
ducting to the Duct Connector may be preventing the
damper from opening.
• Checkthatthebackdraftdamperinthewallorroofcap
pivots freely. These dampers are sometimes mistakenly
painted shut or obstructed by bird and insect debris.