update-backup-bmc

Note: The -update-backup-bmc option is available only with firmware update
container version 19.12.1 and later.
$ sudo docker run --rm --privileged -ti -v /:/hostfs nvfw-dgx2:19.12.1
update_fw BMC --update-backup-bmc

Note: The ability to update the secondary SBIOS using the firmware update container is
available only with firmware update container version 19.12.1 and later.
$ sudo ./<run-file-name>.run sbios_slot --switch-nextboot-slot
$ telinit 1
$ umount /raid
$ sync
$ ipmitool chassis power cycle
$ sudo ./nvfw-dgx2_19.12.1_191204.run sbios_slot --switch-nextboot-
slot
$ telinit 1
$ umount /raid
$ sync
$ ipmitool chassis power cycle