Questions and Answers

  • D
    Douglas GarciaJul 29, 2025
    Why is the water flow insufficient in my Oase Water Filtration System?
    • D
      Deborah JohnsonJul 29, 2025
      Several factors can cause insufficient water flow in your Oase Water Filtration System. The impeller unit, foam filter, filter media, or pipework might be soiled and require cleaning. The inlet strainer could be clogged and needs to be cleaned. The impeller unit may be worn and need replacement. Ensure that the water flow is correctly set.
  • S
    Sharon WalkerAug 3, 2025
    What to do if my Oase Water Filtration System does not start up?
    • E
      Elizabeth MitchellAug 3, 2025
      If your Oase Water Filtration System doesn't start, first check the mains voltage. If the voltage is ok, the impeller unit might be blocked and needs cleaning. Another cause could be air trapped inside the filter, in this case, vent the filter by moving it from side to side to release any trapped air.
  • S
    Shelby PearsonAug 7, 2025
    How to improve the filtering performance of my Oase BioMaster 350?
    • M
      maryturnerAug 7, 2025
      Poor filtering performance in your Oase Water Filtration System can stem from a soiled or worn foam filter in the pre-filter, or from soiled or worn filter media in the filter unit. Clean soiled components or replace worn ones to restore optimal performance.
  • K
    Kimberly JonesAug 13, 2025
    Why is the water heating insufficient in my Oase BioMaster 350?
    • A
      Andrew BellAug 13, 2025
      If your Oase Water Filtration System (with heater) isn't heating water sufficiently, the heater may be defective and require replacement, or it may not be calibrated correctly and need calibration. Also, ensure the water temperature is correctly set on the heater. Insufficient water flow can also cause this issue; refer to the troubleshooting steps for 'Water flow insufficient'.
  • M
    Mitchell RiversAug 17, 2025
    How to reduce noise from my Oase Water Filtration System?
    • M
      Mary CardenasAug 17, 2025
      Increased noise in your Oase Water Filtration System is often due to air trapped in the filter. To resolve this, move the filter from side to side to allow the remaining air to escape.
  • T
    Teresa GriffinAug 23, 2025
    What to do if the Oase Water Filtration System cannot be vented?
    • H
      holdenalejandroAug 23, 2025
      If you're unable to vent your Oase Water Filtration System, the valve box in the pre-filter may be blocked and require cleaning. Also, ensure the filter is installed below the surface of the water.

Summary

BioMaster 250;350;600;850 & BioMaster Thermo 250;350;600;850

Important Safety Instructions

Essential safety guidelines for proper and safe operation of the unit.

Safety Information

Guidelines for use by children and persons with reduced capabilities.

Accessing the Unit

Heater Handling and Installation

Instructions for safely handling, removing, and fitting the heater.

Unit Head Dismantling and Fitting

Instructions for removing and reassembling the unit head.

Commissioning and Start-Up

Expelling Air from the Filter System

Procedure to prime the filter and remove trapped air for proper operation.

Switching the Unit On and Off

Steps for powering on and off the filter unit, including heater safety.

Troubleshooting and Maintenance

Common Malfunctions and Remedies

Lists potential issues like no start-up, low flow, and their solutions.

Oase BioMaster 350 Specifications

General IconGeneral
Flow Rate1100 L/h
Suitable for AquariumsUp to 350 liters
Pre-filter ModuleYes
Power Consumption15 W
Hose Connection16/22 mm
Cable Length1.5 m
UV-C Clarifier IncludedNo
Filter TypeExternal Canister Filter