Questions and Answers

  • S
    Susan GonzalezAug 1, 2025
    What to do if there is no water flow at the water outlets of Oase bitron 18c?
    • S
      sarah41Aug 1, 2025
      If there's no water flow at the water outlets of your Oase Water Pump, it could be due to a blocked flow nozzle. To fix this, disconnect the power supply and switch off the pump. Another possible cause is dirty water outlets, which would require cleaning the flow nozzle or the water outlets.
  • P
    patellindaAug 16, 2025
    Why is my Oase bitron 18c water cloudy?
    • J
      Jason LeAug 16, 2025
      Cloudy water can occur for several reasons. It may be due to a faulty UVC lamp connection, which requires checking the electrical connections. The cleaning rotor or quartz glass tube may be soiled, so cleaning is needed. An incorrect pump flow rate could also be the reason; refer to the installation guide for the correct flow rate. Other causes include brown suspended material or deposits, which means you should remove algae and leaves, and prevent dirt from entering. If the pond is extremely dirty, check the water values and change the water. If the UVC lamp has no capacity, check and replace it after 8,000 hours of use. Finally, an incorrect bypass adjustment can cause cloudiness; check the setting and note the pump capacity.

Summary

1. Symbols

2. Appropriate use of device

Defines the intended application and optimal conditions for the Bitron UVC clarifier.

3. Important Safety Instructions

Provides essential safety precautions to prevent injury and damage during device operation.

4. General Safety Instructions

Details general safety guidelines, including UVC radiation hazards and magnetic field effects.

5. Electrical connection

Explains grounding requirements and proper electrical connection procedures for safe operation.

6. Ground fault circuit interrupter (GFCI) protection

Stresses the importance of using GFCI protection to mitigate electrical shock risks.

7. Installation

7.1 Device overview

Identifies and describes the various components and ports of the Bitron device.

7.2 Setting up the Bitron

Details how to set up the Bitron unit, including hose connections and integration with Biotec systems.

7.3 Hose connection

Gives recommendations and instructions for connecting hoses to the Bitron unit for optimal performance.

8. Placing in service

8.1 Bypass settings

Explains the bypass system and how to adjust it for optimal water flow and cleaning.

9. Maintenance

9.1 Replacing the UVC bulb

Details the step-by-step process for safely replacing the UVC bulb.

9.2 Replace cleaning rotor

Explains how to check for wear and replace the cleaning rotor for optimal function.

10. Cleaning

10.1 Automatic cleaning

Describes the automatic cleaning function of the rotor and its benefits.

10.2 Cleaning the quartz glass sleeve

Provides instructions for cleaning the quartz glass sleeve to maintain UVC efficiency.

10.3 Clean inspection glass

Details the process for cleaning the inspection glass to check device function.