- GB -
20
Remedy of faults
Malfunction Cause Remedy
The water is extremely soiled.
Remove algae and leaves from the pond.
Change the water.
Insufficient delivery rate of the pump Check the installation.
The quartz glass is soiled. Clean the quartz glass.
The quartz glass is scratched.
Replace the quartz glass ( Cleaning the
quartz glass)
If the profile is worn, replace the cleaning
rotor ( Cleaning the quartz glass)
The cleaning rotor is not turning.
Check the inspection window: An alternating
light/dark blue glow indicates that the clea-
ning rotor is rotating.
Clean the cleaning rotor and quartz glass
( Cleaning the quartz glass)
If the delivery rate of the pump is < 10000 l/h,
use an inlet nozzle for driving the cleaning
rotor.
If the profile is worn, replace the cleaning
rotor ( Cleaning the quartz glass)
The UVC lamp capacity is exhausted. Replace the UVC lamp after 8000 operating
hours.
Water remains cloudy (green water).
Incorrect bypass setting Correct the setting, observe the pump capacity.
Inlet nozzle clogged Clean the inlet nozzle. No or insufficient water flow at the outlets
Outlets clogged
Clean the casing ( Cleaning and maintenan-
ce)
Power plug not connected Connect the power plug.
UVC lamp defective Replace the UVC lamp.
Connection defective Check the electrical connection.
UVC lamp is not lit.
Bitron C 55W/72W/110W: The unit has swit-
ched off due to overheating (safety switch-off).
Allow it to cool down; the unit will switch back
on automatically.
Maintenance and cleaning
Attention! Dangerous electrical voltage.
Possible consequences: Death or severe injury.
Protective measures:
Electrical units and installations with a rated voltage of U > 12 V AC or U >30 V DC located in the water:
Isolate the units and installations (switch off and disconnect from the power supply) before reaching into the
water.
Isolate the unit before starting any work.
Secure the unit to prevent unintentional switching on.
Attention! Breakable glass.
Possible consequences: Injury to your hands caused by cuts.
Protective measures: Handle the quartz glass and UVC lamp with care.
Dismantling the unit head
1.
0.
How to proceed:
K
1. Undo the locking screw in the safety engagement catch.
Rotational direction "Lock open" symbol.
2. Press the safety engagement catch, turn the unit head counterclockwise as far as the stop and carefully pull it out of
the casing.
Thoroughly clean the inner and outer surfaces of the casing.
Note!
For safety reasons the UVC lamp can only be switched on when the unit head has been correctly fitted into
the casing.

Table of Contents

Other manuals for Oase Bitron C

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Oase Bitron C and is the answer not in the manual?

Oase Bitron C Specifications

General IconGeneral
BrandOase
ModelBitron C
CategoryWater Filtration Systems
LanguageEnglish

Related product manuals