Section 4: Set-up guide for bottle filler electronics
Factory default settings are for a(n):
UNFILTERED unit
20 second maximum run time
1. Top cap is set aside until program is complete. Remove top cap by
unscrewing two (2) T15 torx screws if needed.
2. Reach hand down between frame and front of cabinet to gently press button
sticking up from top of circuit board (Note: Circuit board runs on low voltage
and will not shock you). A remote button is available. Remove wire tie
bundling it inside bottle filler and feed it through hole in cooler top. You can
then adjust program using button through access panel of cooler.
3. To enter program mode, press and hold button for about 3 seconds. When
you hear a beep, let go of button. You are now in program mode. Pressing
button for an instant will advance to next screen. It will revert back to
operating mode if no button is pressed for 10 seconds.
4. When you enter program mode, display screen will read “UNFILTERED
UNIT.” To access settings for “FILTERED UNIT”, press and hold button for
about 3 seconds. Press button for an instant to advance to next menu item.
5. If you wish to reset filter life counter or bottle counter, press and hold button
for 3 seconds in screen asking corresponding question.
6. Default capacity for filter life counter is 1250 gallons (to match Versafilter).
Press and hold button 3 seconds in “FILTER CAPACITY OF…” screen to
change setting to 3000 gallons (galaxi® green filter media).
7. ”Bottle Filler Set_time” screen is to adjust maximum run time once sensor is
activated. Water flow will stop once container is removed from alcove, but
this feature ensures very little water is wasted if someone tampers with
dispenser.
8. Unit is calibrated at factory, but it is recommended that sensor be re-
calibrated at each install. Also, if you are having problems with sensing of a
bottle, try recalibrating it before calling for service. Press and hold button for
3 seconds to calibrate sensor in “INFRARED SENSITIVITY” screen.
9. Put top cap back on and fasten in place with two (2) torx screws.
You can change the program settings by entering the program mode. To
change the program settings, use the following steps: