95
DISPLAY RANGE/RESOLUTION
Numeric Displays: Range: Resolution:
Dive Number 0 to 24 1
Depth 0 to 399 ft (120 m) 1 ft (.1 m/1 m > 99.9 )
Maximum Depth 399 ft (120 m) 1 ft (.1 m/1 m > 99.9)
FO2 Set Point Air, 21 to 50 % 1 %
PO2 Value 0.00 to 5.00 ATA .01 ATA
Dive Time Remaining 0:00 to 9:59 hr:min 1 minute
Air Time Remaining 0:00 to 9:59 hr:min 1 minute
Total Ascent Time 0:00 to 9:59 hr:min 1 minute
Safety Stop Time 3:00 to 0:00 min:sec 1 second
Decompression Stop Time 0:00 to 9:59 hr:min 1 minute
Elapsed Dive Time 0:00 to 9:59 hr:min 1 minute
Surface Time 0:00 to 23:59 hr:min 1 minute
Dive Log Surface Interval 0:00 to 23:59 hr:min 1 minute
Time to Fly 23:50 to 0:00 hr:min* 1 minute
(* starting 10 min after the dive)
Time to Desaturate 23:50 maximum to 0:00 hr:min* 1 minute
(* starting 10 min. after the dive)
Temperature 0 to 99°F (-9 to 60°C)
Cylinder Pressure 0 to 5000 psi (0 to 352 BAR) 5 psi (.5 BAR)
Special Displays: Occurrence
Diagnostic Display After Manual Activation
Out of Range (- - -) >330/399 feet (>99.9/120 meters)
Gauge Mode Countdown Timer 23:50 to 0:00 hr:min (after violation)
SPECIFICATIONS (CONTINUED)