37EcoComfort
. Operating modesSetting the operating mode
Checking the time setting in the mode “Time control“:
By pressing button for seconds, you activate the verification
function for the time setting. The current time (F) is indicated. The
digits for hour and minute set by the user are shown alternately and
the LED is on at the same time. Push button briefly and the F-
mode is available. This procedure also applies to the other values.
By pressing button for seconds, you can quit this mode
. Technical Data
.. Characteristics
High-efficiency drinking water circulation pump
GB
Voltage supply V
Motor protection No external protection required.
Protection class IP
Insulation class F
Max. relative humidity Max.
Max. pressure . MPa
Inlet pressure Liquid temperature Min. inlet pressure
°C . MPa
°C . MPa
EMC Standard EN--, EN--, EN-, EN-
Noise emission class Less than dB (A)
Ambient temperature - °C
Temperature class TF
Drinking water temperature up to °C