25
NOTE: OilSafe recommends an initial Re-Circulation (“Kidney-Loop”) of the fluid at the first fill, to pre-
filter oils before they are consumed or used. Refer to Re-Circulation (“Kidney-Loop”) Cycle Time Guide in
the Data Tables section (page 39) for approximate run timesto complete single pass filtration of each
tank.
Re-Circulation (“Kidney-Loop”) Mode
STEP 12.
Put the operating valves in the “Re-Circulate” configuration – (left “DOWN”, right “UP”).
STEP 13. Press start button to run each filled Bulk Tank for the approximate times set out in the Re-Circulation (“Kidney-
Loop”) Cycle Time Guide table in the Data Tablessection (page 39).
Dispensing Mode
STEP 1. Place valve handles into Dispense Mode, then press START to start the pump.
STEP 2. Place a clean fluid transfer or storage container under the dispensing tap.
STEP 3. Lift up on the handle See Figure 19 (standard faucet style
illustrated).
STEP 4. Release the handle and the flow will stop.
STEP 5. Press STOP to stop the pump.
STEP 6. Return valve handles to Recirculation Mode.
FIGURE 19: Operating the Standard Dispensing Faucet