45372301TH Rev.2
4-38 /
Oki Data CONFIDENTIAL
4.3.9 Lever path motor (M10)
(4) Remove 2 screws and take off the stacker
motor [5].
Fig. 4-98
(1) Take off the upper cover.
( P.4-1 "4.1.1 Upper cover")
(2) Take off the right cover.
( P.4-1 "4.1.2 Right cover")
(3) Remove 1 screw and 1 connector [1],
remove the bracket (R) [2] and rear cover
open [3].
Fig. 4-99
Fig. 4-100
[5]
[2]
[1]
[3]