45372301TH Rev.2
6-13 /
Oki Data CONFIDENTIAL
[CC96] Lever path abnormality
* If [EAF5] occurs two times consecutively, it becomes a [CC96] error.
[CDE0] Paddle HP abnormality
* If [ED15] occurs two times consecutively, it becomes a [CDE0] error.
Classification Error content
Finisher related service call Lever path abnormality
Check item Measures
Lever path home position sensor
• Sensor check (S15)
• Connector check (P7-4)
• Harness check
Lever path motor
• Motor check (M10)
• Connector check (P18-1)
• Harness check
Finisher control PC board
• Board check
• Connector check (J7, J18)
• Harness check
Parts to be replaced Remark
Lever path home position sensor
Lever path motor
Finisher control PC board
Classification Error content
Finisher related service call Paddle HP abnormality
Check item Measures
Paddle home position sensor
• Sensor check (S3)
• Connector check (P8-4)
• Harness check
Paddle motor
• Motor check (M3)
• Connector check (P5-4)
• Harness check
Finisher control PC board
• Board check
• Connector check (J5, J8)
• Harness check
Parts to be replaced Remark
Paddle home position sensor
Paddle motor
Finisher control PC board