Code meaning
Information Operating
Manual resetting
Refer to the progress of manual reset
Overloading
Remove the load on desktop till it less than 1330N / 136KG /
300LBS(including the desktop) for further operation
Anti-Collision function
It can be used normally after removing the obstacle
Operated continuously
without suitable rest
Make the desk rest around 18minutes for further operation
Code
rES
ovr
E-2
dut
Trouble shooting
Operating
The height between two legs exceed 1 inch. Stop the operation
and reset, refer to Manual reset
Check the cables and ensure they are well connected, and the
height-adjustable desk can be used normally after manual reset
Code
E-4
E-3
Technical Data
Item Data
Input voltage
100~240V AC
output voltage
29V DC
Max loading
1330N / 136KG / 300LBS
Height range
(without desktop)
600~1250mm ( 23.6"49.2")
Duty cycle
2 min on/ 18 min off
The control box detect the current is abnormal, it may be
caused by overloading or signal interference. Please remove
the load or power off to check all the cables' connection, and
then power on again.