7
FRFR
FRFR
FR
ONT PONT P
ONT PONT P
ONT P
ANEL KEY FUNCTIONSANEL KEY FUNCTIONS
ANEL KEY FUNCTIONSANEL KEY FUNCTIONS
ANEL KEY FUNCTIONS
Set Point 1 Lamp
Alar m Lamp Process Var iab le
Set Point 2 Lamp
°F Indicator Set V ar iab le
°C Indicator
1.
INDEX:INDEX:
INDEX:INDEX:
INDEX: Pressing the INDEX key advances the display to the ne xt men u item. Ma y
also be used in conjunction with other keys as noted below .
2
UP ARRUP ARR
UP ARRUP ARR
UP ARR
OO
OO
O
WW
WW
W
::
::
: Increments a value , changes a menu item, or selects the item to ON
in the upper display.
3.
DODO
DODO
DO
WN ARRWN ARR
WN ARRWN ARR
WN ARR
OO
OO
O
WW
WW
W
::
::
: Decrements a value , changes a menu item, or selects the item to
OFF in the upper display.
4.
ENTER:ENTER:
ENTER:ENTER:
ENTER: Pressing ENTER stores the value or the item changed. If not pressed, the
previously stored v alue or item will be retained.
5.
UP ARRUP ARR
UP ARRUP ARR
UP ARR
OO
OO
O
W & ENTER:W & ENTER:
W & ENTER:W & ENTER:
W & ENTER: Pressing these keys sim ultaneously br ings up the
SecondarSecondar
SecondarSecondar
Secondar
yy
yy
y
menmen
menmen
men
uu
uu
u star ting at the auto/man ual selection. Pressing these keys f or 5 seconds will
br ing up the
Secure menSecure men
Secure menSecure men
Secure men
u.u.
u.u.
u.
6
..
..
.
INDEX & DOINDEX & DO
INDEX & DOINDEX & DO
INDEX & DO
WN ARRWN ARR
WN ARRWN ARR
WN ARR
OO
OO
O
WW
WW
W
::
::
: Pressing these keys sim ultaneously will allo w bac king up
one menu item, or if at the first men u item the y will cause the displa y to retur n to the
PrimarPrimar
PrimarPrimar
Primar
y meny men
y meny men
y men
u.u.
u.u.
u.
7.
INDEX & ENTERINDEX & ENTER
INDEX & ENTERINDEX & ENTER
INDEX & ENTER: Pressing these keys simultaneously and holding them for 5
seconds allows recover y from the various error messages. The f ollowing menu items
will be reset:
LPbr:LPbr:
LPbr:LPbr:
LPbr: Loop break
SEnC:SEnC:
SEnC:SEnC:
SEnC: Sensor r ate of change
ALiH:ALiH:
ALiH:ALiH:
ALiH: Alar m inhibit
OPEn InP:OPEn InP:
OPEn InP:OPEn InP:
OPEn InP: Open input error message
bAd InP:bAd InP:
bAd InP:bAd InP:
bAd InP: Bad input error message
ArEA:ArEA:
ArEA:ArEA:
ArEA: Area error message
CHEC CAL:CHEC CAL:
CHEC CAL:CHEC CAL:
CHEC CAL: Check calibr ation error message
Correct the problems associated with the above conditions first before using these reset
keys. More than one error could be present. Caution is advised since sever al items are
reset at one time.
While in the
Primar Primar
Primar Primar
Primar
y ory or
y ory or
y or
SecondarSecondar
SecondarSecondar
Secondar
y meny men
y meny men
y men
u,u,
u,u,
u, if no key is pressed for a per iod of 30 seconds,
the displa y will retur n to the HOME position displaying the PV and SV values . The time is
increased to 1 minute when in the
SecureSecure
SecureSecure
Secure
menmen
menmen
men
uu
uu
u.
NONO
NONO
NO
TE:TE:
TE:TE:
TE:
To move to the
PrimarPrimar
PrimarPrimar
Primar
y meny men
y meny men
y men
u u
u u
u quic kly from any other menu, press the
UP ARRUP ARR
UP ARRUP ARR
UP ARR
OO
OO
O
WW
WW
W
&
ENTER ENTER
ENTER ENTER
ENTER keys follo w ed b y pressing the
INDEX INDEX
INDEX INDEX
INDEX &
DODO
DODO
DO
WN ARRWN ARR
WN ARRWN ARR
WN ARR
OO
OO
O
W W
W W
W keys.
METHOD FOR SET UP OF A HEAMETHOD FOR SET UP OF A HEA
METHOD FOR SET UP OF A HEAMETHOD FOR SET UP OF A HEA
METHOD FOR SET UP OF A HEA
T / COOL CONTRT / COOL CONTR
T / COOL CONTRT / COOL CONTR
T / COOL CONTR
OLOL
OLOL
OL
WITH SELF WITH SELF
WITH SELF WITH SELF
WITH SELF
TUNETUNE
TUNETUNE
TUNE
Deter mine if the process is predominantly heating or cooling. An extr uder, f or example, is
predominantly cooling when r unning product. An environmental chamber can be either
heating or cooling. (For explanation of menu items see pages 12 & 13.)
If the process is predominantly cooling, set S1St to dir and S2St to rE. If the process is
predominantly heating, set S1St to rE and S2St to dir. Redirect SP1 to output A or B as