9.2.20 ADDRESS (Multipoint Communications Device Address)
Address is used to give each meter a unique address while on a local area
network using the optional RS-485 board.
MENU MIN/MAX/MENU *
BUTTON BUTTON
MAIN MENU SUB MENU DESCRIPTION
“ADDRES”: MULTIPOINT COMMUNICATIONS
DEVICE ADDRESS
Enter address as an integer value:
“000” “000” to “199”
(“001”)
* Press the ‘MIN’ button to show the value on the display.
The ‘MIN’ button also allows you to change the position of the digit being
changed.
The ‘MAX’ button changes the value of the digit to be displayed.
Press the ‘MENU’ button to store the changes and advances the meter to
the next configuration (“DAT FT”).
The underlined item is the factory preset value.
9.2.21 DAT FT (Data Format)
Data format is used to set all the parameters to be transmitted via the
optional RS-232 or RS-485 serial communications board.
Data format allows you to select:
• whether to transmit Alarm 1 or 2 status character [DAT.1]
• whether to transmit peak and valley status character [DAT.2]
• whether or not the data transmitted is filtered or unfiltered [DAT.3 & DAT.4]
• whether or not to transmit the peak and valley readings [DAT.5 & DAT.6]
• the type of separator [DAT.7]
• whether or not to transmit the unit of measure [DAT.8]