Connection 
to the 
electrical 
power 
mains
 
 
 
W
ARNING
 
This 
apparatus 
must  be 
ear
thed.
 
 
 
The oven is only for domestic use. 
The feed voltage and the absorbed power are as indicated on the data plate attached to 
the left-hand side upright, which can be seen when the oven door is open. 
Connecting  must  be  carried  out  by  qualified  personnel  and  in accordance  with  the 
regulations currently in force. 
 
 
The  manufacturer  cannot  be  held  responsible  for  any damages  to  persons  or objects 
caused by failure to observe these instructions. 
 
 
If the supply cord is damaged, it must be replaced by the manufacturer, its service agent 
or similarly qualified persons in order to avoid a hazard. 
 
 
The  oven  must  be  connected  to  the  mains  through  a  multipole  circuit  breaker  with 
a contact-to-contact  gap  of  at  least  3 mm,  making  sure  that  the  earth  wire  is  not 
disconnected.  For  connecting  use a flexible  cable  of the  H05V2V2-F  3x1,5  mm
2   
type 
remembering to make it long enough to allow the oven to be removed from its housing 
unit when maintenance work is required. 
 
 
 
To  connect   the   cable  to  the  oven 
proceed as follows (see Fig. 2): 
-  Remove the lid (1) by unfastening the 
three  screws  (2). Unfasten  the  two 
screws  (3)  for  the  cable  holder  and 
feed  the  cable  through  the  opening 
immediately below the cover. 
-  Remove about 12 cm of the outside 
insulation    from    the  cable   and 
shorten the two active wires (live and 
neutral) to 6 cm, leaving long the one 
to    be  connected  to the  main  earth 
terminal on the terminal box; remove 
about  1 cm  of  the  main  insulation 
from  the three  wires  and  connect 
them  correctly  to  the  terminal  box, 
remembering to respect the polarities. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Fig. 2 
-  Tighten the two screws (3) of the cable holder and put the lid (1) back on with the three 
screws (2). 
 
WARNING: 
If  the  electrical  supply  is  restricted,  means  of  all-pole  
disconnection 
must  be  accessible  and 
incorporated  in the fixed wiring  in 
accordance 
with the wiring 
rules.