6.3 Push the switch into “I”, the lamp be on; push into “0”, the lamp be off.
6.4 Push the switch into “IIIIII”, the motor will be on “lowmidhigh”
three speeds, push into “0”, the motor will be off.
7. USE AND MAINTENANCE
It is recommended to operate the appliance prior to cooking.
It is recommended to leave the appliance in operation for 15 minutes after cooking is
terminated in order to completely eliminate cooking vapours and odours.
If the appliance is not used, please turn off.
Don’t use or stop use if the appliance is damaged especially the supply cord and the case.
If the supply cord is damaged, it must be replaced by the manufacturer, its service agent
or similarly qualified persons in order to avoid a hazard.
Don’t immerse the appliance in liquid.
The exhaust air must not be discharge into a flue which is used for exhausting fumes from
appliance burning gas or other fuels.
Regulations concerning the discharge of air have to be fulfilled.
The proper function of the cooker hood is conditioned by the regularity of the maintenance
operations, in particular, the active carbon filter.
The anti-grease filters capture the grease particles suspended in the air, and are therefore
subject to clogging according to the frequency of the use of the appliance.
In order to prevent fire hazard, it is recommendable to clean the filter at a maximum of 2
months by carrying out the followings:
-Remove the filters from the cooker hood and wash them in a solution of water and neutral
liquid detergent, leaving to soak.
-Rinse thoroughly with warm water and leave to dry.
-The filters may also be washed in the dishwasher.
The aluminum panels may alter in color after several washes. This is not cause for
customer complaint nor replacement of panels.
Clean the fan and other surface of the cooker hood regularly using cloth moistened with
denatured alcohol of non abrasive liquid detergent.
Before any repair on the cooker hood, detach all plugs.
Replace filters approximately every 4 months.