3
Lamp Replacement
Warning: Before attempting to replace the lights, ensure that the appliance is switched off and unplugged
from the wall.
Remove the aluminium filter.
Press the lamp face and turn anti-clockwise to remove.
Replace with the same type of bulb (GU10 Base, 3W MAX).
o Max Wattage: 2 x 3W
o Voltage Range: 220 – 240V AC
o ILCOS D Code: DR-3/65/1B-H-GU10-46/50
Replace the aluminium filter.