OMNI 4000/7000 Installation Guide – Rev H
The display is showing
system data and menus
Power source malfunction
An overcurrent condition overloaded a
fuse, tripping it
A front panel ribbon cable malfunction
• Check the heartbeat.
• Check that the front panel keys
beep when pressed.
• Check the system power.
• Use OMNIPANEL to verify the flow
computer is functioning properly.
• If there is normal front panel
functionality through OMNIPANEL,
check the front panel ribbon cable:
− Inspect for damage to cable and
no bent pins.
− Verify the cable is installed with
the correct orientation
Keypress functions for screen
navigation includes a beep
with each key press
• Replace the front panel with a spare
to test.
Battery voltage LED
indicator illuminated red
Battery voltage indicator
illuminated green
Power not applied
LED burned out
Coin cell battery needs replace
• Verify that the flow computer is
powered on.
• Test the front panel. If there is a
response, the LED is burned out.
Replace the CPU card (optional).
• Replace the cell battery