OMNI 4000/7000 Operations and Maintenance Guide Rev F
3-31
OMNICONNECT® Operations
2.
a. Expand the Control tree.
b. Select Prover to see the Prover
Control screen to the right.
3.
a. In the Volume/Mass Prove Control
drop-down box, select a Meter Run.
b. Click the Prove Request button.
4.
The prove sequence begins after a prove is requested (see Section 3.5.3 Prove Sequence
for more information). Status messages will appear in the Volume Prove Status field and
the run information box will populate automatically. At any time, click Prove Abort to stop
the prove sequence process while a prove is running.
3.5.6 Remote Prove Request
You can use Modbus communications to remotely trigger a prove. Write to the appropriate
address from the following command points to execute a prove sequence:
1732 Meter 1 Prove Request
1733 Meter 2 Prove Request