Model
Maxi-
mum
appli-
cable
motor
ca-
paci-
ty
[kW]
Recommended wire size [mm2]
Main power supply input (L1/R, L2/S, L3/T)
When DC reactor (DCR) is
used
Without DC reactor (DCR)
HHD mode HND mode
Allowable tempera-
ture (Note 1)
Cur-
rent
value
[A]
Allowable tempera-
ture (Note 1)
Cur-
rent
value
[A]
60°C 75°C 90°C 60°C 75°C 90°C
- 3G3M1-
A4015-ECT
2.2 2.0 2.0 2.0 4.2 2.0 2.0 2.0 7.3
3G3M1-
A4022-ECT
- 2.0 2.0 2.0 4.4 2.0 2.0 2.0 8.2
- 3G3M1-
A4022-ECT
3 2.0 2.0 2.0 5.8 2.0 2.0 2.0 11.3
3G3M1-
A4030-ECT
-
- 3G3M1-
A4030-ECT
3.7 2.0 2.0 2.0 7.3 2.0 2.0 2.0 13.0
3G3M1-
A4040-ECT
-
- 3G3M1-
A4040-ECT
5.5 2.0 2.0 2.0 10.1 3.5 2.0 2.0 16.8
3G3M1-
A4055-ECT
- 2.0 2.0 2.0 10.6 3.5 2.0 2.0 17.3
3G3M1-
A4075-ECT
3G3M1-
A4055-ECT
7.5 2.0 2.0 2.0 14.4 5.5 2.0 2.0 23.2
3G3M1-
A41
10-ECT
3G3M1-
A4075-ECT
11 5.5 2.0 2.0 21.1 8.0 3.5 3.5 33.0
3G3M1-
A4150-ECT
3G3M1-
A4110-ECT
15
8.0 3.5 2.0 28.8 14.0 5.5 5.5 43.8
3G3M1-
A4185-ECT
3G3M1-
A4150-ECT
18.5 14.0 5.5 3.5 35.5 22.0 8.0 5.5 52.3
3G3M1-
A4220-ECT
3G3M1-
A4185-ECT
22 14.0 5.5 5.5 42.2 22.0 14.0 8.0 60.6
- 3G3M1-
A4220-ECT
30 22.0 14.0 8.0 57.0
38.0
*1
14.0 14.0 77.9
Model
Maxi-
mum
appli-
cable
motor
ca-
paci-
ty
[kW]
Recommended wire size [mm2]
Inverter output (U, V, W)
HHD mode HND mode
HHD mode HND mode
Allowable tempera-
ture (Note 1)
Cur-
rent
value
[A]
Allowable tempera-
ture (Note 1)
Cur-
rent
value
[A]
60°C 75°C 90°C 60°C 75°C 90°C
3G3M1-
A4004-ECT
- 0.4 2.0 2.0 2.0 1.8 - - - -
2 Design
2-24
M1 Series EtherCAT Type User’s Manual (I670)

Table of Contents

Related product manuals