Model
Maxi-
mum
appli-
cable
motor
ca-
paci-
ty
[kW]
Recommended wire
size [mm2]
Inverter ground (G)
HHD mode HND mode
Allowable tempera-
ture (Note 1)
60°C 75°C 90°C
3G3M1-A2001-ECT - 0.1 2.0 2.0 2.0
3G3M1-A2002-ECT 3G3M1-A2001-ECT 0.2 2.0 2.0 2.0
- 3G3M1-A2002-ECT 0.4 2.0 2.0 2.0
3G3M1-A2004-ECT - 2.0 2.0 2.0
- 3G3M1-A2004-ECT 0.75 2.0 2.0 2.0
3G3M1-A2007-ECT - 2.0 2.0 2.0
- 3G3M1-A2007-ECT 1.1 2.0 2.0 2.0
3G3M1-A2015-ECT - 1.5 2.0 2.0 2.0
- 3G3M1-A2015-ECT 2.2 2.0 2.0 2.0
3G3M1-A2022-ECT - 2.0 2.0 2.0
- 3G3M1-A2022-ECT 3 2.0 2.0 2.0
3G3M1-A2037-ECT - 3.7 2.0 2.0 2.0
- 3G3M1-A2037-ECT 5.5 3.5 3.5 3.5
3G3M1-A2055-ECT - 3.5 3.5 3.5
3G3M1-A2075-ECT 3G3M1-A2055-ECT 7.5 5.5 5.5 5.5
3G3M1-A2110-ECT 3G3M1-A2075-ECT 11 5.5 5.5 5.5
3G3M1-A2150-ECT 3G3M1-A2110-ECT 15 5.5 5.5 5.5
3G3M1-A2220-ECT 3G3M1-A2150-ECT 18.5 8.0 8.0 8.0
- 3G3M1-A2220-ECT 22 8.0 8.0 8.0
Three-phase 400-V class (Panel internal temperature 50°C or less)
Model
Maxi-
mum
appli-
cable
motor
ca-
paci-
ty
[kW]
Recommended wire size [mm2]
Main power supply input (L1/R, L2/S, L3/T)
When DC reactor (DCR) is
used
Without DC reactor (DCR)
HHD mode HND mode
Allowable tempera-
ture (Note 1)
Cur-
rent
value
[A]
Allowable tempera-
ture (Note 1)
Cur-
rent
value
[A]
60°C 75°C 90°C 60°C 75°C 90°C
3G3M1-
A4004-ECT
- 0.4 2.0 2.0 2.0 0.9 2.0 2.0 2.0 1.7
- 3G3M1-
A4004-ECT
0.75 2.0 2.0 2.0 1.5 2.0 2.0 2.0 2.7
3G3M1-
A4007-ECT
- 2.0 2.0 2.0 1.6 2.0 2.0 2.0 3.1
- 3G3M1-
A4007-ECT
1.1 2.0 2.0 2.0 2.1 2.0 2.0 2.0 3.9
3G3M1-
A4015-ECT
- 1.5 2.0 2.0 2.0 3.0 2.0 2.0 2.0 5.9
2 Design
2-23
M1 Series EtherCAT Type User’s Manual (I670)
2-3 Wiring
2
2-3-4 Wiring for Main Circuit Terminals

Table of Contents