Parameter
No.
Function name Monitor or data range
Default
data
Setting
during
RUN
Unit
M25 ROM Version
0 to 9999
100 - -
M26
Transmission Error Transaction
Code for RS-485 Port1
1: Improper FC (Non-existent
parameter block specified)
[RTU]
2: Improper address (Non-ex-
istent parameter number
specified) [RTU]
3: Improper data (Range error)
[RTU]
7: NAK (Link priority, no right,
write disabled) [RTU]
71: Checksum error, CRC er-
ror
72: Parity error
73: Framing error, overrun er-
ror, buffer full
0 - -
M27
Final Frequency Reference Moni-
tor on Alarm Monitor
-32,768 to 32,767
0 - -
M28
Final Torque Command Monitor
on Alarm
-327.68 to 327.67
0 - %
M29
Final Torque Current Command
Monitor on Alarm
-327.68 to 327.67
0 - %
M30
Final Magnetic flux command
Monitor on Alarm
-327.68 to 327.67
0 - %
M31
Final Frequency Reference Moni-
tor on Alarm
0.00 to 655.35
0 - Hz
M32
Output Frequency Monitor on
Alarm without Slip Compensation
-32768 to 32767
0 - -
M33 Output Torque Monitor on Alarm
-327.68 to 327.67
0 - %