Parameter
No.
Function name Monitor or Data Range
Default
data
Setting
during
RUN
Unit Page
E36
Frequency Detection
Level 2 (FDT2/FDT4)
0.0 to 590.0 Hz
60.0
Availa-
ble
Hz
page
7-89
E37
1st Overload Early
Warning Detection
Level
0.00 ; 0.01 to 176.0
0.00 : Disable
0.01 to 176.0 A
* Setting range from 1%(HHD)
to 200%(ND) of the rated in-
verter current.
21
Availa-
ble
A
page
7-82
E38
1st Overload Early
Warning Detection
Timer / Low Current
detection level (OL,
LOC)
0.01 to 600.00 s
10
Availa-
ble
s
page
7-82
E39
Display Coefficient 1
for Transport Time /
Auxiliary Display Coef-
ficient 1 for Speed
Monitor
0.000 to 9999
1
Availa-
ble
-
page
7-76
E42 Operator Display Filter
0.0 to 5.0 s
0.5
Availa-
ble
s page 3-3
4 Parameter List
4-87
M1 Series Standard Type User's Manual (I669)
4-2 List of Parameters by Group
4
4-2-2 Parameter E (Terminal Functions)