Parameter
No.
Function name Monitor or Data Range
Default
data
Setting
during
RUN
Unit Page
E131
Frequency Calculation
Operation T
arget 1
0: Up/Down keys on Operator
1: Voltage input to terminal
[AI1]
2: Current input to terminal
[AI2](AII)
3: Voltage input to terminal
[AI2](AIV)
5: Pulse train input
6: RS-485 communication
7: Fieldbus (Reserved)
1
- -
page
7-118
E132
Frequency Calculation
Operation Target 2
0: Up/Down keys on Operator
1: Voltage input to terminal
[AI1]
2: Current input to terminal
[AI2](AII)
3: Voltage input to terminal
[AI2](AIV)
5: Pulse train input
6: RS-485 communication
7: Fieldbus (Reserved)
2
- -
page
7-118
E133
Frequency Calculation
Operator Selection
0: Addition (E131 + E132)
1: Subtraction (E131 - E132)
2: Multiplication (E131 x E132)
0 - -
page
7-118
E134
Frequency Addition
Amount
0.00 to 590.00 Hz
0.00 - Hz
page
7-118
E135
Frequency Addition
Sign Selection
0: Frequency command +
E134
1: Frequency command -
E134
0 - -
page
7-118
E139
Overvoltage/Overcur-
rent Restart Function
Selection
0: Trip immediately
4: Restart at the frequency se-
lected by E152
0 - -
page
7-58
4 Parameter List
4-95
M1 Series Standard Type User's Manual (I669)
4-2 List of Parameters by Group
4
4-2-2 Parameter E (Terminal Functions)