Parameter
No.
Function name Monitor or Data Range
Default
data
Setting
during
RUN
Unit Page
E123
2nd AVR Function Se-
lection
0: Disable
1: Enable
1 - -
page
7-121
E124
Energy-saving Opera-
tion Function Selection
0: Normal operation
1: Energy-saving operation
0 - -
page
7-141
E125
1st 2-step Accelera-
tion/ Deceleration
switching Condition
Selection
0: Switching by 2CH terminal
1: Switching by setting
2: Forward and reverse
3: Switching by RT1, RT2 ter-
minals
0
- -
page
5-43
E126
2nd 2-step Accelera-
tion/Deceleration
Switching Condition
Selection
0: Switching by 2CH terminal
1: Switching by setting
2: Forward and reverse
3: Switching by RT1, RT2 ter-
minals
0
- -
page
5-43
E127
1st 2-step Accelera-
tion Switching Fre-
quency
0.00 to 590.00 Hz
0.00 - Hz
page
5-43
E128
2nd 2-step Accelera-
tion Switching Fre-
quency
0.00 to 590.00 Hz
0.00 - Hz
page
5-43
E129
1st 2-step Decelera-
tion Switching Fre-
quency
0.00 to 590.00 Hz
0.00 - Hz
page
5-43
E130
2nd 2-step Decelera-
tion Frequency
0.00 to 590.00 Hz
0.00 - Hz
page
5-43
4 Parameter List
4-94
M1 Series Standard Type User's Manual (I669)