60 
6 
Checking Input Data 
 
Make sure that the settings 
(Input) in the Variables tab page 
are correct. 
 
   
   
(3)  Setting Output Data 
Register the following output data. 
- Slot1(NX-SL3500)Output Data Set1 
- Slot1(NX-SL3500)Output Data Set2 
 
Select a safety controller in the 
Solution Explorer pane of Power 
PMAC IDE. 
 
Display the Variables tab page. 
[Slot1(NX-SL3500)Output Data 
Set1] 
Registering Node1/Unit2 
(NX-SID800) 
 
Click New in the Variables tab 
page, and register 4 variables 
shown on the right. 
 
 
FSoE Master CMD  #x7020:01  USINT 
Group:  Module 1(NX-SL3500).Output Data Set 1 
Datatype:  USINT 
Count:  1 
 
Safety Output 1st Word  #x7021:01  UINT 
FSoE Master CRC_0  #x7020:03  UINT 
FSoE Master Conn_ID  #x7020:02  UINT 
Group:  Module 1(NX-SL3500).Output Data Set 1 
Datatype:  UINT 
Count:  3