At-
trib-
ute
ID
(hex)
Parameter name Description
Attrib-
ute
Data type Value (hex)
SQE Test Errors Number of times a SQE test error mes-
sage was generated.
Read UDINT 0 (always)
Deferred Transmis-
sions
The number of frames for which the first
attempt to send was delayed because the
media was busy
.
Read
UDINT Current val-
ue
Late Collisions The number of collisions detected in
packets that were sent after 512 bit times.
Read UDINT Current val-
ue
Excessive Colli-
sions
The number of frames that failed to be
sent because of excessive collisions.
Read UDINT Current val-
ue
MAC Transmit Er-
rors
The number of frames that failed to be
sent due to an internal MAC sublayer
transmission error
.
Read
UDINT Current val-
ue
Carrier Sense Er-
rors
The number of times the carrier sense
condition was lost.
Read UDINT Current val-
ue
Frame Too Longs The number of frames received that ex-
ceeded the maximum allowed frame size.
Read UDINT Current val-
ue
MAC Receive Er-
rors
The number of frames that could not be
received through the interface due to an
internal MAC sublayer reception error
.
Read
UDINT Current val-
ue
07 Interface Type Interface type Read USINT 02 (always)
0B Interface Control List of settings supported by the interface Read Struct ---
Capability Bits Settings supported by the interface Read DWORD
*2
Speed/Duplex Ar-
ray Count
The number of interface speed/duplex
lists
Read USINT 00 (always)
0C HC Interface Coun-
ters
Counters related to packet transmission
and reception on high capacity interfaces
Read Struct ---
HCInOctets The number of octets received through
the interface. This counter is the 64-bit
edition of In Octets.
Read ULINT Current val-
ue
HCInUnicastPkts The number of unicast packets received
through the interface. This counter is the
64-bit edition of In Unicast Packets.
Read ULINT Current val-
ue
HCInMulticastPkts The number of multicast packets received
through the interface.
Read ULINT Current val-
ue
HCInBroadcastPkts The number of broadcast packets re-
ceived through the interface.
Read ULINT Current val-
ue
HCOutOctets The number of octets sent through the in-
terface. This counter is the 64-bit edition
of Out Octets.
Read ULINT Current val-
ue
HCOutUnicastPkts The number of unicast packets sent
through the interface. This counter is the
64-bit edition of Out Unicast Packets.
Read ULINT Current val-
ue
HCOutMulti-
castPkts
The number of multicast packets sent
through the interface.
Read ULINT Current val-
ue
HCOutBroad-
castPkts
The number of broadcast packets sent
through the interface.
Read ULINT Current val-
ue
Appendices
A-10
CK3E-series Programmable Multi-Axis Controller Users Manual Hardware (I610)

Table of Contents

Other manuals for Omron CK5M-CPU1 1 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron CK5M-CPU1 1 Series and is the answer not in the manual?

Omron CK5M-CPU1 1 Series Specifications

General IconGeneral
BrandOmron
ModelCK5M-CPU1 1 Series
CategoryController
LanguageEnglish

Related product manuals