Page #14 background imageLoading...
Page #14 background image
D4N
2-conduit Models
Note: Unless otherwise specified, a tolerance of r0.4 mm applies to all dimensions.
Roller Lever (Resin Lever, Resin Roller)
D4N-5@20
D4N-6@20
D4N-8@20
17.5 dia. × 6.8
resin roller
Two, 4
+0.15
dia. holes
Depth: 5
0
30
Cap
27.5
20.5
20.5 × 20.5
11
±0.2
47
±1
40
±1
(27)
21.5
42
±0.2
(3)
56 max.
47
39
±0.2
25 dia.
2.5
5.4
9
±0.2
26R
18
20
±0.1
40
±0.1
42
±0
.1
22
±0.1
14.2
Resin lever
2.15±0.05R
mounting
holes
Conduit
cap
Roller Lever (Metal Lever, Resin Roller)
D4N-5@22
D4N-6@22
D4N-8@22
17.5 dia. × 6.8
resin roller
Two, 4
+0.15
dia. holes
Depth: 5
0
30
Cap
27.5
20.5
11
±0.2
21.5
42
±0.2
(3)
56 max.
47
25 dia.
2.5
5.4
9
±0.2
18
20
±0.1
40
±0.1
42
±0.1
22
±0.1
14.2
26R
45
±1
39.5
±1
(31)
39
±0.2
Metal lever
20.5 × 20.5
2.15±0.05R
mounting
holes
Conduit cap
Plunger
D4N-5@31
D4N-6@31
D4N-8@31
Two, 3±0.05
dia. holes
Two, 4
+0.15
dia. holes
Depth: 5
0
30
Cap
20.5
42
±0.2
(3)
56 max.
47
25 dia.
2.5
5.4
9
±0.2
OP
20
±0.1
40
±0.1
42
±0.1
22
±0.1
14.2
(31.5)
21.5
11
±0.2
25
±0.1
12 dia.
39
±0.2
6-dia. resin plunger
2.15±0.05R
mounting
holes
Conduit cap
Roller Plunger
D4N-5@32
D4N-6@32
D4N-8@32
9.5 dia. × 5
resin roller
Two, 4
+0.15
dia. holes
Depth: 5
0
30
Cap
20.5
42
±0.2
(3)
56 max.
47
25 dia.
2.5
5.4
9
±0.2
OP
25.2
20
±0.1
40
±0.1
42
±0.1
22
±0.1
14.2
11
±0.2
(31.5)
21.5
39
±0.2
20.5 × 20.5
2.15±0.05R
mounting
holes
Conduit cap
Snap-action (1NC/1NO) (2NC), Slow-action (2NC)
(3NC)
Note: Variation occurs in the simultaneity of contact opening/closing
operations of 2NC, 2NC/1NO, and 3NC contacts. Check
contact operation.
*1.Only for snap-action models.
*2.Reference value.
*3.For safe use, always make sure that the minimum values or greater
are provided.
Model
Operating characteristics
D4N-
@
120
D4N-
@
220
D4N-
@
B20
D4N-
@
D20
D4N-
@
122
D4N-
@
222
D4N-
@
B22
D4N-
@
D22
D4N-@131
D4N-@231
D4N-@B31
D4N-@D31
D4N-
@
132
D4N-
@
232
D4N-
@
B32
D4N-
@
D32
Operating force
OF max.
5 N 5 N 6.5 N 6.5 N
Release force RF min. 0.5 N 0.5 N 1.5 N 1.5 N
Pretravel PT 18q to 27q 18q to 27q 2 mm 2 mm
Overtravel OT min. 40q 40q 4 mm 4 mm
Movement differential
MD max.
*1
14q 14q 1 mm 1 mm
Operating position OP --- ---
18
r0.5 mm
28.2
r0.8 mm
Total travel TT *2 (80q)(80q) (6 mm) (6 mm)
Direct opening travel
DOT min.
*3
50q 50q 3.2 mm 3.2 mm
Direct opening force
DOF min.
*3
20 N 20 N 20 N 20 N
Slow-action (1NC/1NO) (2NC/1NO)
*1.This PT value is possible when the NC contacts are open (OFF).
*2.This PT value is possible when the NO contacts are closed (ON).
*3.Only for MBB models.
*4.Reference value for MBB models.
*5.Only for MBB models.
*6.Reference value.
*7.For safe use, always make sure that the minimum values or
greater are provided.
Model
Operating characteristics
D4N-
@
A20
D4N-
@
C20
D4N-
@
E20
D4N-@F20
D4N-
@
A22
D4N-
@
C22
D4N-
@
E22
D4N-@F22
D4N-
@
A31
D4N-
@
C31
D4N-
@
E31
D4N-@F31
D4N-
@
A32
D4N-
@
C32
D4N-
@
E32
D4N-@F32
Operating force OF max. 5 N 5 N 6.5 N 6.5 N
Release force RF min. 0.5 N 0.5 N 1.5 N 1.5 N
Pretravel PT *1 18q to 27q 18q to 27q 2 mm 2 mm
PT (2nd)
*2
(44q)(44q) (2.9 mm) (2.9 mm)
PT *3
27.5q to
36.5q
27.5q to
36.5q
2.8 mm 2.8 mm
PT (2nd)
*4
(18q)(18q) (1 mm) (1 mm)
Overtravel OT min. 40q 40q 4 mm 4 mm
Operating position
OP --- ---
18
r0.5 mm
28.2
r0.8 mm
OP *5 --- ---
17.4
r0.5 mm
28
r0.8 mm
Total travel TT *6 (80q)(80q) (6 mm) (6 mm)
Direct opening travel
DOT min.
*7
50q 50q 3.2 mm 3.2 mm
Direct opening force
DOF min.
*7
20 N 20 N 20 N 20 N
http://www.ia.omron.com/
14
(c)Copyright OMRON Corporation 2007 All Rights Reserved.

Other manuals for Omron D4N Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron D4N Series and is the answer not in the manual?

Omron D4N Series Specifications

General IconGeneral
Voltage Rating250 VAC, 30 VDC
Ingress ProtectionIP67
Actuator TypePlunger
Current Rating10 A
Housing MaterialPlastic
CategorySwitch
Connection MethodScrew terminals
Operating Speed0.05 mm/s to 0.5 m/s
StandardsUL 508
Mechanical Life15, 000, 000 operations minimum
Electrical Life500, 000 operations
Contact Configuration1NC/1NO, 2NC