34
Precautions
Fiber Units
Installation
Tightening Force
The tightening force applied to the Fiber Unit should be as fol-
lows:
Screw-mounting Model Cylindrical Model
Use a proper-sized wrench.
Cutting Fiber
• Insert a fiber into the Fiber Cutter and determine the length
of the fiber to be cut.
• Press down the Fiber Cutter in a single stroke to cut the fi-
ber.
• Cut a thin fiber as follows:
Connection
• Do not pull or press the fiber units. The fiber units withstand
tensile or compression force of 9.8 N or 29.4 N maximum.
• Do not bend the fiber unit beyond the permissable bending
radius given under Ordering Information.
• Do not bend the edge of the fiber units (excluding the E32-
T#R and E32-D#R).
• Do not apply excess force on the fiber units.
• The fiber head may break due to excessive vibration. A one
turn loop may reduce the effect of vibrations:
Fiber Units Clamping torque
M3/M4 screw 0.78 Nm max.
M6 screw/6-mm dia. column 0.98 Nm max.
1.5-mm dia. column 0.2 Nm max.
2-mm dia./3-mm dia. column 0.29 Nm max.
E32-T12F 5-mm dia. Teflon model
0.78 Nm max.
E32-D12F 6-mm dia. Teflon model
E32-T16 0.49 Nm max.
E32-R21 0.59 Nm max.
E32-M21
0.49 Nm max. for up to 5 mm from
front end, 0.78 Nm max. for more
than 5 mm from front end
E32-T16P
E32-T16PR
E32-T24S
E32-L24L
E32-L25L
E32-T16J
E32-T16JR
0.29 Nm max.
E32-ET16W
E32-ET16WR
0.3 Nm max.
Toothed washers
Spring mounting clip
Nuts
(attachment)
Retaining screw
(flat head or
sunken head)
A
An attachment is
temporarily fitted
to a thin fiber be-
fore shipment.
B
Secure the attach-
ment after adjust-
ing the position of
it in the direction
indicated by the
arrow.
C
Insert the fiber to
be cut into the
E39-F4.
D
Finished state
(proper cutting
state)
Note: Insert the fiber in the direction indicated by
the arrow.
Thin fiber
attachment
(E39-F9)
Temporarily
fitted
E39-F4
fiber cutter
Two holes for thin fiber
Three holes
for standard
fiber (2.2-mm dia.)
Approx. 0.5 mm
Insertion direction
Amplifier Unit
Fiber Unit
20 mm min.
20 mm min.
Fiber Unit
Nylon wireholder
Tape
A one-turn loop can