EasyManua.ls Logo

Omron E3X-N User Manual

Omron E3X-N
14 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
Auto-Tuning Fiber-Optic Sensor
E3X-N
High Performance DC Amplifier with
Pushbutton Sensitivity Adjustment
Maintenance is made easier with
pushbutton sensitivity adjustment
Sensing distance is up to 100% longer
than standard amplifiers
Choose either single channel or four
channel models
Compact housing: 32 mm and 10 mm
housing widths
Four amplifiers in a single housing
saves space and wiring
Four fiber-optic cables can be mounted
directly next to each other without
mutual interference
Ordering Information
AMPLIFIERS
Type Single channel Four channel
Off-delay timer None Provided Provided
Remote teach input None Provided Provided
Part number
NPN output E3X-NT11 E3X-NT21 E3X-NM11
PNP output E3X-NT41 E3X-NT51 E3X-NM41
FIBER-OPTIC CABLES
Please see the E32 Fiber-Optic Cables section.
ACCESSORIES
Description Part number
Replacement protective cover for E3X-NT
E39-G8
Replacement protective cover for E3X-NM
E39-G9
Question and Answer IconNeed help?

Do you have a question about the Omron E3X-N and is the answer not in the manual?

Omron E3X-N Specifications

General IconGeneral
Output Current100 mA max.
Protection CircuitReverse polarity protection, output short-circuit protection
TypeFiber Amplifier
Light SourceRed LED
Power Supply Voltage12-24 VDC ±10%
Output TypeNPN
Connection Type2m cable
Housing MaterialABS
Operating Temperature-25 to 55°C (with no icing or condensation)

Summary

Ordering Information

AMPLIFIERS

Details product part numbers and configurations for amplifier models.

FIBER-OPTIC CABLES

References section for compatible fiber-optic cables.

ACCESSORIES

Lists optional accessories for the sensor.

Specifications

Output Circuit Diagrams

Nomenclature

Operation

Choosing the Right Teaching Method

Guide to selecting the most suitable sensitivity setting method.

Maximum Sensitivity Setting

With/Without-Object Teaching

No-Object Teaching

Sensitivity Adjustment

No-object Teaching

Procedure for setting sensitivity without a sensing object.

With/Without-object Teaching

Procedure for setting sensitivity with and without an object.

No-Object Teaching with Initial Operating Level Compensation

Remote Teaching Function

Timer Set Function (E3X-NM)

Optical Axis Adjustment (Flashing Function)

Dimensions

AMPLIFIER

Provides dimensional drawings for the amplifier units.

Accessories

Installation

Fiber Cable Installation

Instructions for connecting and disconnecting fiber cables.

Amplifier Units

Mounting

Removal

Procedure for removing the amplifier from its mounting.

Related product manuals