E3NC
12
I/O Circuit Diagrams
NPN Output
PNP Output
Model
Operation
mode
Timing chart
L/D indicator
Output circuit
E3NC-LA21
E3NC-SA21
Light-ON
Dark-ON
E3NC-LA7
E3NC-LA24
E3NC-SA7
E3NC-SA24
Light-ON
Dark-ON
Model
Operation
mode
Timing chart
L/D indicator
Output circuit
E3NC-LA51
E3NC-SA51
Light-ON
Dark-ON
E3NC-LA9
E3NC-LA54
E3NC-SA9
E3NC-SA54
Light-ON
Dark-ON
Incident light
No incident light
Lit
Not lit
ON
OFF
Operate
Reset
OUT indicator
(orange)
Output
transistor
Load
(e.g., relay)
(Between brown and
black (orange) leads)
ch1/
ch2
lit.
L
Load
Load
OUT2 indicator
(orange)
Brown
Black
Control output
ch1
Control output
ch2
External
input
Orange
Blue
Pink
10 to
30 VDC
OUT1 indicator
(orange)
Display
Photoelectric
sensor main
circuit
Incident light
No incident light
Lit
Not lit
ON
OFF
Operate
Reset
OUT indicator
(orange)
Output
transistor
Load
(e.g., relay)
(Between brown and
black (orange) leads)
ch1/
ch2
lit.
D
Incident light
No incident light
Lit
Not lit
ON
OFF
Operate
Reset
OUT indicator
(orange)
Output
transistor
Load
(e.g., relay)
(Between brown and
black leads)
lit.
L
1
4
2
3
Load
Brown
Black
Control output
External
input
Blue
Note: 1, 2, 3 and 4 are pin terminals of M8 Connector Type.
Orange
10 to
30 VDC
OUT indicator
(orange)
Display
Photoelectric
sensor main
circuit
Incident light
No incident light
Lit
Not lit
ON
OFF
Operate
Reset
OUT indicator
(orange)
Output
transistor
Load
(e.g., relay)
(Between brown and
black leads)
lit.
D
Incident light
No incident light
Lit
Not lit
ON
OFF
Operate
Reset
OUT indicator
(orange)
Output
transistor
Load
(e.g., relay)
(Between blue and
black (orange) leads)
ch1/
ch2
lit.
L
Photoelectric
sensor main
circuit
Load
Load
OUT2 indicator (orange)
Control output ch2
Control output
ch1
Brown
Black
Pink
Orange
Blue
10 to
30 VDC
OUT1 indicator
(orange)
Display
External
input
Incident light
No incident light
Lit
Not lit
ON
OFF
Operate
Reset
OUT indicator
(orange)
Output
transistor
Load
(e.g., relay)
(Between blue and
black (orange) leads)
ch1/
ch2
lit.
D
Incident light
No incident light
Lit
Not lit
ON
OFF
Operate
Reset
OUT indicator
(orange)
Output
transistor
Load
(e.g., relay)
(Between blue and
black leads)
lit.
L
1
2
4
3
Photoelectric
sensor main
circuit
Load
Control output
Brown
Black
Orange
Blue
10 to
30 VDC
OUT indicator
(orange)
Display
External
input
Note: 1, 2, 3 and 4 are pin terminals of M8 Connector Type.
Incident light
No incident light
Lit
Not lit
ON
OFF
Operate
Reset
OUT indicator
(orange)
Output
transistor
Load
(e.g., relay)
(Between blue and
black leads)
lit.
D

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron E3C-LD11 and is the answer not in the manual?

Omron E3C-LD11 Specifications

General IconGeneral
BrandOmron
ModelE3C-LD11
CategoryAccessories
LanguageEnglish

Related product manuals