22
Installation Section 2-1
E5GN Mounting to the Panel
1,2,3... 1. For waterproof mounting, waterproof packing must be installed on the
Controller. Waterproofing is not possible when group mounting several
Controllers.
Waterproof packing is not necessary when there is no need for the water-
proofing function.
2. Insert the E5GN into the mounting hole in the panel.
3. Push the adapter from the terminals up to the panel, and temporarily fasten
the E5GN.
4. Tighten the two fastening screws on the adapter. Alternately tighten the
two screws little by little to maintain a balance.Tighten the screws to a
torque of 0.29 to 0.39 N·m.
2-1-2 Removing the Temperature Controller from the Case
The Temperature Controller can be removed from the case to perform mainte-
nance without removing the terminal leads. This is possible for only the E5CN,
E5AN, and E5EN, and not for the E5CN-U or E5GN. Check the specifications
of the case and Temperature Controller before removing the Temperature
Controller from the case.
E5CN
1,2,3... 1. Insert a flat-blade screwdriver into the two tool insertion holes (one on the
top and one on the bottom) to release the hooks.
2. Insert the flat-blade screwdriver in the gap between the front panel and
rear case, and pull out the front panel slightly. Hold the top and bottom of
the front panel and carefully pull it out toward you, without applying unnec-
essary force.
Panel
Adapter
Waterproof packing
E5GN
Flat-blade screwdriver
(Unit: mm)
Tool insertion hole